Permit: T22CM07347

Parcel: 132111770

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
09/25/2026 RSBU - Building Final  Re-inspection required 9/25/26: label panel, insulate hose bib, paint or seal all exterior wood, add insulation to hot copper line at water heater, water heater requires an enclosure. A ladder to access roof is required. I did not inspect anything on the inside of home. Stopped inspection-additional items may be noted.
10/28/2026 RSBU - Building Final  Re-inspection required 10/28/2026
All corrections made. Walked rest of unit. Pending change 15A and 20A breakers in kitchen, living room, bedroom, smoke detector and lights to be AFCI. Kitchen countertops needs to GFCI and receptacle below sink. Add pipe to temperature and pressure relief valve down with an air gap to ground. Add engineer letter stating truss design not required per approved plan.