Inspection History Details
Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2026 | RSBU - Building Final | Re-inspection required | 9/25/26: label panel, insulate hose bib, paint or seal all exterior wood, add insulation to hot copper line at water heater, water heater requires an enclosure. A ladder to access roof is required. I did not inspect anything on the inside of home. Stopped inspection-additional items may be noted. | |
| 10/28/2026 | RSBU - Building Final | Re-inspection required | 10/28/2026 All corrections made. Walked rest of unit. Pending change 15A and 20A breakers in kitchen, living room, bedroom, smoke detector and lights to be AFCI. Kitchen countertops needs to GFCI and receptacle below sink. Add pipe to temperature and pressure relief valve down with an air gap to ground. Add engineer letter stating truss design not required per approved plan. |