Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address NEW:
4120 S MELPOMENE WY
Apply Date:
08/19/2022
Applicant:
James Kazal
Description:
R-Bedroom Addition

Permit Reviews

Permit Number - T22CM06407
Permit Status: Inspections
Permit Description: R-Bedroom Addition
Start Date Submittal Complete Date Status  
08/19/2022 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 09/12/2022 COMPLETED Review Details
07/24/2023 RESIDENTIAL NEW DWELLING v.5 07/24/2023 APPROVED Review Details
06/05/2023 RESIDENTIAL NEW DWELLING v.3 06/12/2023 REQUIRES RESUBMIT Review Details
03/10/2023 RESIDENTIAL NEW DWELLING v.2 03/10/2023 REQUIRES RESUBMIT Review Details
06/23/2023 RESIDENTIAL NEW DWELLING v.4 07/21/2023 REQUIRES RESUBMIT Review Details
12/16/2022 RESIDENTIAL NEW DWELLING v.1 01/17/2023 REQUIRES RESUBMIT Review Details
07/24/2023 RESTAMP - RESIDENTIAL v.1 07/25/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - T22CM06407
Permit Status: Inspections
Permit Description: R-Bedroom Addition
Total Outstanding Activity Conditions - 1
Date Name
01/14/2023 HVAC Calculations must be submitted and approved prior to Mechanical Final

Conditions

Permit Number - T22CM06407
Permit Status: Inspections
Permit Description: R-Bedroom Addition
Date Description Comments
07/25/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact.

Outstanding Inspections

Permit Status: Inspections
Permit Number: T22CM06407
Permite Description: R-Bedroom Addition
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
11/07/2023 COT - RSBU - Preslab N/A Not Applicable
12/15/2023 RSEL - Electrical Progress N/A Not Ready 12/15/23: not ready needed roof nailing inspection to cover and dry in
12/15/2023 RSME - Mechanical Progress N/A Not Ready
12/15/2023 RSPL - Plumbing Progress N/A Not Ready
12/29/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Partial Pass Mechanical, electrical, & plumbing rough-in are complete. Exterior shear walls are properly installed and nailed off. Window frames are not installed they are a long lead item, was told that they won't be delivered until February 2024. Have approved for stucco work to be performed but holding back 12" around all windows and doors that are not installed at this time. Okay to insulate and sheet rock interior walls with the same requirements as stucco around windows.
11/30/2023 COT - FCON - Sprinkler - Final N/A Partial Pass Overhead and hydro approved on only the new construction.

Completed Inspections

Permit Status: Inspections
Permit Number: T22CM06407
Permit Description: R-Bedroom Addition
Total Completed Inspections - 10
Date Description Inspector Results Comments
09/14/2023 COT - RSPL - Sewer Passed 9/12/23: partial for interior underground exterior of house will need to be reinspected due to the rain today

9/14/23 ok to backfill once photos of tracer wire is sent.
09/14/2023 COT - RSPL - Rough Soil Passed
11/07/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
12/20/2023 COT - RSBU - Roof Nailing Passed 12/20/23: existing roof sheathing is good to cover
08/08/2024 COT - FCON - Sprinkler - Final Passed
09/03/2024 COT - RSEL - Outdoor Lighting Passed
09/03/2024 COT - RSPL - Plumbing Final Passed
09/03/2024 COT - RSEL - Electrical Final Passed
09/03/2024 COT - RSME - Mechanical Final Passed
09/03/2024 RSBU - Building Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OWNER-BUILDER AFFIDAVIT_V1.PDF DOCUMENTS VIEW
CONS-A1_V1.PDF DOCUMENTS VIEW
CONS-CONS-2 PLAN SET_V3_V2.PDF DOCUMENTS VIEW
CONS-CONS-2 PLAN SET_V2_V2.PDF DOCUMENTS VIEW
RESPONSE TO COMMENTS 6-2-2023_V2.PDF DOCUMENTS VIEW