Inspection Status: Partial Pass
Inspection History: COT - RSBU - Preslab
| Date |
Description |
Inspector |
Results |
Comments |
| 10/03/2023 |
COT - RSBU - Preslab |
|
Partial Pass |
10/3/23: Preslab for new addition and interior of house per plan. Partial pass Master patio and back patio footings and columns pending. |
| 11/06/2023 |
COT - RSBU - Preslab |
|
Re-inspection required |
11/6/23: exterior footings failed inspection. Maintain minimum 3" from earth and 1" from forms to reinforcing. Reinforcing collapsed against the form upon inspection. |
| 11/07/2023 |
COT - RSBU - Preslab |
|
Not Applicable |
|