Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Apply Date:
03/31/2022
Applicant:
vance goodman
Description:
R-LAUNDRY ROOM; GARAGE and PORCH ADDITION

Permit Reviews

Permit Number - T22CM02376
Permit Status: Complete
Permit Description: R-LAUNDRY ROOM; GARAGE and PORCH ADDITION
Start Date Submittal Complete Date Status  
03/31/2022 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 04/28/2022 COMPLETED Review Details
05/10/2022 RESUBMITTAL 05/13/2022 COMPLETED Review Details
02/10/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 02/10/2023 APPROVED Review Details
04/14/2023 RESIDENTIAL NEW DWELLING v.1 05/11/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - T22CM02376
Permit Status: Complete
Permit Description: R-LAUNDRY ROOM; GARAGE and PORCH ADDITION
Total Outstanding Activity Conditions - 1
Date Name
05/13/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Conditions

Permit Number - T22CM02376
Permit Status: Complete
Permit Description: R-LAUNDRY ROOM; GARAGE and PORCH ADDITION
Date Description Comments
05/13/2022 SHOP DRAWINGS REQUIRED FOR TRUSS DRAWINGS

Outstanding Inspections

Permit Status: Complete
Permit Number: T22CM02376
Permite Description: R-LAUNDRY ROOM; GARAGE and PORCH ADDITION
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
05/18/2022 RSME - Mechanical Progress N/A Canceled {Activity date: 05/18/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - }
02/01/2023 COT - RSBU - Stem Wall/Retaining Wall N/A Not Applicable
10/26/2022 COT - RSPL - Gas Pressure Test N/A Not Ready
10/27/2022 COT - RSME - Mechanical Final N/A Not Ready
10/27/2022 COT - RSEL - Outdoor Lighting N/A Not Ready
04/07/2023 COT - RSEL - Electrical Final N/A Not Ready
04/12/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Partial Pass Partial per intermediates

4-7-23: 1-Gas line is not per approved plans; and has changed from tank to tankless. 2-No test on gas, nor DWV piping. 3-Install vertical fire blocking at 10' max spacing at all furr-out walls. Per R302.11#1.2. 4-Complete fireblocking per R302.11.1. 5-Seal all fireblocking.

4/12/23: provide new revision to plans for gas line to tankless water heater and change pipe to 3/4" ID.
OK to proceed at risk.
02/22/2023 COT - RSBU - Preslab N/A Partial Pass top-out grout lift for garage/addition
04/07/2023 COT - LCBU - Framing N/A Re-inspection required 4-7-23: 1-Gas line is not per approved plans; and has changed from tank to tankless. 2-No test on gas, nor DWV piping. 3-Install vertical fire blocking at 10' max spacing at all furr-out walls. Per R302.11#1.2. 4-Complete fireblocking per R302.11.1. 5-Seal all fireblocking.

Completed Inspections

Permit Status: Complete
Permit Number: T22CM02376
Permit Description: R-LAUNDRY ROOM; GARAGE and PORCH ADDITION
Total Completed Inspections - 17
Date Description Inspector Results Comments
05/25/2022 COT - RSEL - Service Relocation Passed {Activity date: 05/25/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP. INCR clearance code for TEP. Called in at 2:02.}
05/25/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 05/25/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - CODE INCR}
01/18/2023 COT - RSPL - Rough Soil Passed
01/18/2023 COT - RSPL - Sewer Passed
02/01/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
03/07/2023 COT - RSBU - Roof Nailing Passed
03/07/2023 COT - RSBU - Exterior Clips/Sheathing Passed
07/18/2023 RSBU - Building Final Passed
07/18/2023 COT - RSPL - Yard Water Line Passed
07/18/2023 COT - RSPL - Plumbing Final Passed
07/18/2023 COT - RSPL - Gas Pressure Test Passed
07/18/2023 COT - RSME - Mechanical Final Passed
07/18/2023 COT - RSEL - Outdoor Lighting Passed
07/18/2023 COT - RSEL - Electrical Final Passed
07/18/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
07/18/2023 COT - RSBU - Preslab Passed
07/18/2023 COT - LCBU - Framing Passed

Documents

File Name Document Type  
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
LOFC_LETTEROFCOMPLETION.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
RESPONSE LETTER T22CM02376 520 N. EASTVIEW AVE 4.14.23_V1.PDF DOCUMENTS VIEW
CONS-520 N EASTVIEW AVE CD REV 2 4.14.23_V1.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW
BALLARD TRUSS PLAN ENGINEERING STAMPED 1 23 23 T22CM02376_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW