Permit: T22CM01556
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
1356 N APACHE DR
Address NEW:
1356 N APACHE DR
Apply Date:
03/03/2022
Applicant:
Jose Quintero
Description:
DPLX SWC2152 T21-M0059
Permit Reviews
Permit Number - T22CM01556
Permit Status: Complete
Permit Description: DPLX SWC2152 T21-M0059
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/03/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 04/01/2022 | COMPLETED |
| 04/08/2022 | RESUBMITTAL | 04/23/2022 | COMPLETED |
| 04/23/2022 | RESUBMITTAL | 05/04/2022 | COMPLETED |
| 09/07/2022 | RESUBMITTAL | 09/16/2022 | COMPLETED |
| 11/01/2023 | RESIDENTIAL NEW DWELLING v.1 | 11/16/2023 | APPROVED |
Conditions
Permit Number - T22CM01556
Permit Status: Complete
Permit Description: DPLX SWC2152 T21-M0059
| Date | Description | Comments |
|---|---|---|
| 03/03/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
| 03/03/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) | |
| 09/16/2022 | This building permit approval is without public sewer connection review or approval. It is strictly the responsibility of the owner and/or person doing the work to ensure that the appropriate review and approval to connect is obtained from Regional Wastewater Reclamation Department (RWRD) wastewater provider or Pima County DEQ approval of/and alternative disposal system. It is required that owner and/or person doing the work solicit all requisite approvals from the wastewater provider prior to obtaining this building construction permit. RWRD connection information is available at www.pima.gov/wwm/developer.htm | |
| 09/16/2022 | A Pima County Wastewater sign off required prior to issuance of permit. | |
| 02/29/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: T22CM01556
Permite Description: DPLX SWC2152 T21-M0059
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/29/2022 | COT - LCPL - Plumbing Intermediate | N/A | Canceled | {Activity date: 03/29/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - } |
| 03/29/2022 | RSME - Mechanical Progress | N/A | Canceled | {Activity date: 03/29/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - } |
| 10/26/2022 | COT - RSBU - Firewall/Fire Barrier/Firestop | N/A | Not Ready | |
| 11/27/2023 | COT - RSEL - Construction Power | N/A | Re-inspection required | |
| 10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready | |
| 04/18/2024 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 4/18/24: weep screed clearance must be 4" above grade (not meeting clearance throughout), water heater T&P drain must terminate 6" above grade, water heaters missing pan per code P2801.6 and pan shall drain no less than 6" above grade, A/C condensate drain must be UV coated, Arc-fault breakers required at kitchen circuits and laundry circuit. Cut clean outs to grade and cap, light switches not made up in unit 1, smoke alarms missing in unit. |
Completed Inspections
Permit Status: Complete
Permit Number: T22CM01556
Permit Description: DPLX SWC2152 T21-M0059
Total Completed Inspections - 19