Inspection Status: Not Ready
Inspection History: COT - RSPL - Plumbing Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
COT - RSPL - Plumbing Final |
|
Not Ready |
|
| 03/03/2022 |
COT - RSPL - Plumbing Final |
RPARSON1 |
Prior to Final Inspectn |
Entered by RPARSON1 - PIMA COUNTY WASTEWATER SIGN OFF REQUIRED PRIOR TO ISSUANCE OF FINAL STATUS. |
| 04/18/2024 |
COT - RSPL - Plumbing Final |
|
Re-inspection required |
4/18/24: weep screed clearance must be 4" above grade (not meeting clearance throughout), water heater T&P drain must terminate 6" above grade, water heaters missing pan per code P2801.6 and pan shall drain no less than 6" above grade, A/C condensate drain must be UV coated, Arc-fault breakers required at kitchen circuits and laundry circuit. Cut clean outs to grade and cap, light switches not made up in unit 1, smoke alarms missing in unit. |
| 04/19/2024 |
COT - RSPL - Plumbing Final |
|
Passed |
|