Permit Reviews
Permit Number - T21CM05522
Permit Status: Issued
Permit Description: Single Family Residence
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/06/2021 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 07/30/2021 | COMPLETED |
| 08/04/2021 | RESUBMITTAL | 08/24/2021 | COMPLETED |
| 08/24/2021 | RESUBMITTAL | 08/30/2021 | COMPLETED |
| 10/13/2021 | REVISION - - 1ST | 10/20/2021 | COMPLETED |
| 10/22/2021 | RESUBMITTAL | 11/01/2021 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T21CM05522
Permit Status: Issued
Permit Description: Single Family Residence
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 11/01/2021 | This building permit approval is without public sewer connection review or approval. It is strictly the responsibility of the owner and/or person doing the work to ensure that the appropriate review and approval to connect is obtained from Regional Wastewater Reclamation Department (RWRD) wastewater provider or Pima County DEQ approval of/and alternative disposal system. It is required that owner and/or person doing the work solicit all requisite approvals from the wastewater provider prior to obtaining this building construction permit. RWRD connection information is available at www.pima.gov/wwm/developer.htm |
| 11/01/2021 | PIMA COUNTY WASTEWATER SIGN OFF REQUIRED PRIOR TO ISSUANCE OF FINAL STATUS. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T21CM05522
Permite Description: Single Family Residence
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - RSPL - Sewer | N/A | Not Ready | |
| 10/26/2022 | COT - RSEL - Construction Power | N/A | Not Ready | |
| 11/02/2023 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 11/2/23: Address needs to be posted on house (4" font), main water line needs to be insulated and wrapped for UV protection, A/C unit needs refrigerant lock caps, seal all penetrations coming from condensate drains, condensate drains need to be coated for UV Damage, weep screed needs 6" clearance from grade all around, front porch and upstairs receptacle must be WR, missing receptacles at upstairs master bathroom vanity, receptacle at island is under a eaves greater than 6" (E3901.4.3), water hammer arrestor missing at dishwasher, insulate hot water line under kitchen sink, anti tip missing at range. |
| 11/02/2023 | COT - RSEL - Outdoor Lighting | N/A | Re-inspection required | 11/2/23: Address needs to be posted on house (4" font), main water line needs to be insulated and wrapped for UV protection, A/C unit needs refrigerant lock caps, seal all penetrations coming from condensate drains, condensate drains need to be coated for UV Damage, weep screed needs 6" clearance from grade all around, front porch and upstairs receptacle must be WR, missing receptacles at upstairs master bathroom vanity, receptacle at island is under a eaves greater than 6" (E3901.4.3), water hammer arrestor missing at dishwasher, insulate hot water line under kitchen sink, anti tip missing at range. |
| 11/02/2023 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 11/2/23: Address needs to be posted on house (4" font), main water line needs to be insulated and wrapped for UV protection, A/C unit needs refrigerant lock caps, seal all penetrations coming from condensate drains, condensate drains need to be coated for UV Damage, weep screed needs 6" clearance from grade all around, front porch and upstairs receptacle must be WR, missing receptacles at upstairs master bathroom vanity, receptacle at island is under a eaves greater than 6" (E3901.4.3), water hammer arrestor missing at dishwasher, insulate hot water line under kitchen sink, anti tip missing at range. |
| 10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready | |
| 11/02/2023 | RSBU - Building Final | N/A | Re-inspection required | 11/2/23: Address needs to be posted on house (4" font), main water line needs to be insulated and wrapped for UV protection, A/C unit needs refrigerant lock caps, seal all penetrations coming from condensate drains, condensate drains need to be coated for UV Damage, weep screed needs 6" clearance from grade all around, front porch and upstairs receptacle must be WR, missing receptacles at upstairs master bathroom vanity, receptacle at island is under a eaves greater than 6" (E3901.4.3), water hammer arrestor missing at dishwasher, insulate hot water line under kitchen sink, anti tip missing at range. |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM05522
Permit Description: Single Family Residence
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/17/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 05/17/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} | |
| 05/17/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 05/17/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - NR} | |
| 05/17/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 05/17/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} | |
| 05/27/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 05/27/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} | |
| 05/27/2022 | COT - RSBU - Preslab | Passed | {Activity date: 05/27/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} ; {Activity date: 05/25/2022; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Not ready please wrap ABS and no plans on site } ; {Activity date: 05/19/2022; Status: Denied; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Denied. Rebar dowels need to alternate directions. Footings state number four rebar 12 inches each way. Hold downs are incorrect and STHD number tens are missing.} |
|
| 05/27/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 05/27/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} ; {Activity date: 05/19/2022; Status: Denied; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Denied. Rebar dowels need to alternate directions. Footings state number four rebar 12 inches each way. Hold downs are incorrect and STHD number tens are missing.} | |
| 07/26/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 07/26/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} | |
| 07/27/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 07/27/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - CODE ECO} | |
| 05/09/2023 | COT - RSPL - Sewer | Passed | ||
| 05/09/2023 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 05/09/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 05/09/2023 | COT - RSEL - Construction Power | Passed | Duplicate inspection. 5/9/2023 | |
| 05/09/2023 | RSME - Mechanical Progress | Passed | ||
| 05/30/2023 | COT - HCBU - Interior Shear Bracing | Passed | ||
| 04/05/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 04/05/2024 | COT - RSEL - Electrical Final | Passed | ||
| 04/05/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
| 04/05/2024 | COT - RSME - Mechanical Final | Passed | ||
| 04/05/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 04/05/2024 | RSBU - Building Final | Passed |