Permit: T21CM05522

Parcel: 126161160


Addresses:

4280 E BROADWAY BL

Inspection Status: Not Ready

Inspection History: COT - RSEL - Outdoor Lighting

Date Description Inspector Results Comments
10/27/2022 COT - RSEL - Outdoor Lighting Not Ready
04/05/2024 COT - RSEL - Outdoor Lighting Passed
COT - RSEL - Outdoor Lighting Re-inspection required 11/2/23: Address needs to be posted on house (4" font), main water line needs to be insulated and wrapped for UV protection, A/C unit needs refrigerant lock caps, seal all penetrations coming from condensate drains, condensate drains need to be coated for UV Damage, weep screed needs 6" clearance from grade all around, front porch and upstairs receptacle must be WR, missing receptacles at upstairs master bathroom vanity, receptacle at island is under a eaves greater than 6" (E3901.4.3), water hammer arrestor missing at dishwasher, insulate hot water line under kitchen sink, anti tip missing at range.