Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T21CM05522

Parcel: 126161160


Addresses:

4280 E BROADWAY BL

Inspection Status: Not Ready

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
10/27/2022 RSBU - Building Final  Not Ready
04/05/2024 RSBU - Building Final  Passed
RSBU - Building Final  Re-inspection required 11/2/23: Address needs to be posted on house (4" font), main water line needs to be insulated and wrapped for UV protection, A/C unit needs refrigerant lock caps, seal all penetrations coming from condensate drains, condensate drains need to be coated for UV Damage, weep screed needs 6" clearance from grade all around, front porch and upstairs receptacle must be WR, missing receptacles at upstairs master bathroom vanity, receptacle at island is under a eaves greater than 6" (E3901.4.3), water hammer arrestor missing at dishwasher, insulate hot water line under kitchen sink, anti tip missing at range.