Permit: T21CM01954
Permit Details
Apply Date:
03/04/2021
Applicant:
Description:
C of O - new single story fire station of 13,914 s.f. with four apparatus bays, thirteen dormitories, fitness
Permit Reviews
Permit Number - T21CM01954
Permit Status: Complete
Permit Description: C of O - new single story fire station of 13,914 s.f. with four apparatus bays, thirteen dormitories, fitness
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/04/2021 | COMMERCIAL - NEW | 04/20/2021 | COMPLETED |
| 06/22/2021 | RESUBMITTAL | 09/21/2021 | COMPLETED |
| 10/26/2021 | REVISION - - 1ST | 10/29/2021 | COMPLETED |
| 12/29/2021 | REVISION - - 2ND | 01/04/2022 | COMPLETED |
Conditions
Permit Number - T21CM01954
Permit Status: Complete
Permit Description: C of O - new single story fire station of 13,914 s.f. with four apparatus bays, thirteen dormitories, fitness
| Date | Description | Comments |
|---|---|---|
| 07/28/2021 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
| 07/28/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) | |
| 07/28/2021 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. | |
| 07/28/2021 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. | |
| 07/28/2021 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. | |
| 07/28/2021 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. | |
| 07/28/2021 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. | |
| 07/28/2021 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. | |
| 07/28/2021 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
Outstanding Inspections
Permit Status: Complete
Permit Number: T21CM01954
Permite Description: C of O - new single story fire station of 13,914 s.f. with four apparatus bays, thirteen dormitories, fitness
Total Outstanding Inspections - 28
Completed Inspections
Permit Status: Complete
Permit Number: T21CM01954
Permit Description: C of O - new single story fire station of 13,914 s.f. with four apparatus bays, thirteen dormitories, fitness
Total Completed Inspections - 15
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2021 | COT - LCPL - Rough Soil | Passed | {Activity date: 10/21/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap All west side rough ok to backfill. Under slab complete.} ; {Activity date: 10/15/2021; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa 2 separate 4” lines to sewer and grease interceptor in east side phase 1, ok to backfill} |
|
| 03/04/2022 | COT - LCEL - Grounding/Bonding | Passed | {Activity date: 03/04/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap Ground rods ok} ; {Activity date: 11/15/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap East exterior service ufer ok} |
|
| 03/25/2022 | COT - LCBU - Masonry Pregrout | Passed | {Activity date: 03/25/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap Last wall for for grout - east side support area to top out at 19’4" ok.} ; {Activity date: 03/04/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VVERA1 - pa S apparatus wall to 24’ E apparatus wall to 18’ N apparatus wall to 17’ All ok to grout.} ; {Activity date: 02/23/2022; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - - Partial, 4th lift (18’) of the apparatus bay, also north end pillars} ; {Activity date: 02/16/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa Ok to grout: Captains office to top out at 28’, West apparatus wall to top out at 24’, South apparatus columns to 14} ; {Activity date: 02/14/2022; Status: Cancelled; Inspector: DQUINN; Comment: Entered by NGARCIA3 - ca Per Jose} ; {Activity date: 02/10/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa East apparatus bay to 5’4 West apparatus bay to 22’ South columns ok to 10’8” Support area walls ok to 5’4” } ; {Activity date: 01/31/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa NW corner ok to top out. East fitness room ok to 19’ 4” } ; {Activity date: 01/19/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa Dorm walls ok to grout to top out } ; {Activity date: 01/18/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VVERA1 - pa 3rd lift on dorm walls ok to grout. } ; {Activity date: 01/07/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VVERA1 - pa 2nd lift of west half of building ok to grout} ; {Activity date: 12/30/2021; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa 5 north side apparatus bay piers, ok to grout 1st lift} ; {Activity date: 12/28/2021; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa West 1/2 ok to grout 1st lift. 12 apparatus bay piers - 6 north and 6 south, ok to pour 1st lift.} |
|
| 04/04/2022 | COT - LCBU - Roof Nailing | Passed | {Activity date: 04/04/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
| 04/06/2022 | COT - LCPL - Yard Water Line | Passed | {Activity date: 04/06/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 05/09/2022 | COT - BULD - SWG Clearance | Passed | {Activity date: 05/09/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - CODE} | |
| 08/23/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 08/23/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - CODE ECO} | |
| 08/23/2022 | COT - LCEL - Construction Power | Passed | {Activity date: 08/23/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap Clear eco} |
|
| 09/16/2022 | COT - LCME - Mechanical Above Ceiling | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} ; {Activity date: 05/24/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa All above inspections in east side support rooms ok to hard lid.} ; {Activity date: 04/12/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VVERA1 - Pa hood duct smoke and wrap ok.} ; {Activity date: 03/25/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - pa} |
|
| 09/16/2022 | COT - LCPL - Plumbing Above Ceiling | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} ; {Activity date: 05/24/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Pa} | |
| 09/16/2022 | COT - LCEL - Electrical Above Ceiling | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} ; {Activity date: 05/24/2022; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Pa} | |
| 10/20/2022 | COT - FCON - Hood System - Final | Passed | {Activity date: 10/20/2022; Status: Approved; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - } | |
| 10/20/2022 | COT - LCPL - Plumbing Final | Passed | {Activity date: 10/20/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 07/28/2021; Status: Prior to Final Inspectn; Inspector: LBOWERS; Comment: Entered by LBOWERS1 - WATER QUALITY REPORT REQUIRED PRIOR TO FINAL INSPECTION} | |
| 01/09/2023 | SITE - Zoning Final | Passed | N/A | |
| 01/09/2023 | COT - FCON - Fire - Final | Passed |