| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/22/2023 | RESIDENTIAL NEW DWELLING v.1 | 04/04/2023 | REQUIRES RESUBMIT |
| 04/16/2025 | RESIDENTIAL NEW DWELLING REVISION v.2 | 05/23/2025 | REQUIRES RESUBMIT |
| 05/25/2023 | RESIDENTIAL NEW DWELLING v.3 | 06/06/2023 | REQUIRES RESUBMIT |
| 09/24/2025 | RESIDENTIAL NEW DWELLING REVISION v.3 | 10/24/2025 | APPROVED |
| 02/11/2025 | RESIDENTIAL NEW DWELLING v.1 | 03/11/2025 | APPROVED |
| 02/10/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/11/2025 | REQUIRES RESUBMIT |
| 06/13/2023 | RESIDENTIAL NEW DWELLING v.4 | 06/22/2023 | APPROVED |
| 02/04/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/05/2025 | APPROVED |
| 04/04/2025 | RESIDENTIAL NEW DWELLING REVISION v.1 | 04/04/2025 | REQUIRES RESUBMIT |
| 04/17/2023 | RESIDENTIAL NEW DWELLING v.2 | 05/09/2023 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - T20CM08450
Permit Status: Issued
Permit Description: New SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/29/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Conditions
Permit Number - T20CM08450
Permit Status: Issued
Permit Description: New SFR
| Date | Description | Comments |
|---|---|---|
| 10/31/2023 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 10/31/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 06/03/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T20CM08450
Permite Description: New SFR
Total Outstanding Inspections - 16
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2022 | COT - LCBU - Framing | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - LCPL - Plumbing Intermediate | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - FCON - Sprinkler - Final | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - RSPL - Yard Water Line | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - RSEL - Electrical Underground | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - RSEL - Construction Power | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - RSPL - Rough Soil | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | RSME - Mechanical Progress | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - RSPL - Gas Pressure Test | N/A | Canceled | Inspection Canceled |
| 01/29/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 1/29/25 1. SW7 not per plan; blocking is missing, anchor bolts are missing, nail spacing not not per plan. 2. A35s missing per detail 4 on 4.2 3. ICF is covering headers on main floor couldn't verify H1 headers. 4. Detail 6 on 4.2 calls for H2.5 not H3. 5. Stopped inspections, more items may be called out in next inspection. |
| 11/29/2024 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | Not ready. Contractor is only about 1/4 of the way thru. Most workers called out today. |
| 10/31/2024 | COT - RSBU - Stem Wall/Retaining Wall | N/A | Partial Pass | Retaining wall footing (approximately 35 feet) at Southeast area of house. OK to place concrete in progress areas. |
| 01/29/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 1/29/25 1. SW7 not per plan; blocking is missing, anchor bolts are missing, nail spacing not not per plan. 2. A35s missing per detail 4 on 4.2 3. ICF is covering headers on main floor couldn't verify H1 headers. 4. Detail 6 on 4.2 calls for H2.5 not H3. 5. Stopped inspections, more items may be called out in next inspection. |
| 06/06/2025 | RSPL - Plumbing Progress | N/A | Partial Pass | main water line approved. okay to backfill progress areas. shading is required. 6/6/2025 |
| 09/24/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | 9-24-25: not applicable |
| 11/14/2024 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 12/11/23: reinforcement per plan at garage footings and retaining wall. Ok to proceed. 5/7/24: reinforcement per plan at north footings ok to proceed. Ok for 7ft lift at CMU wall on north east side of home. Ok for 6ft lift ICF at north east side of house 7/24/24: reinforcement per plan at north footings ok to proceed. 9/24/24: rebar inspection for BBQ area footer and slab and front entry footers. Ok to proceed. 10/8/24: reinforcement at main floor ICF blocks per plan ok to proceed. 10/10/24: reinforcement at ICF blocks for bbq mono pour per plan ok to proceed. 11/14/24: reinforcement not per plan at 6' CMU at south east wall. |
Completed Inspections
Permit Status: Issued
Permit Number: T20CM08450
Permit Description: New SFR
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/23/2024 | COT - RSBU - Preslab | Passed | Ok to cover progress areas. | |
| 05/10/2024 | COT - RSPL - Sewer | Passed | 5/10/24: passed ok to backfill. | |
| 03/12/2025 | COT - RSBU - Interior Shear Bracing | Passed | Sheetrock nailing,throughout. OK to,tape and texture interior walls. | |
| 04/11/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 04/11/2025 | COT - RSBU - Roof Nailing | Passed | ||
| 04/11/2025 | COT - RSBU - Stem Wall/Retaining Wall | Passed | ||
| 04/11/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 05/12/2025 | BULD - Electrical Clearance | Passed | 5-12-25, electrical panel okay to be energized. Bonding at gas lines still required and to be verified prior to final. Contractor is missing mud ring for ufer access but provided me with pictures showing ufer, acorn clamp and # copper wire. Apparently, access to ufer will not be possible so I explained 2 grounding rods with #4 copper may be required at the main panel to satisfy code for building final. ECO clearance issued to TEP. | |
| 08/06/2025 | COT - RSBU - Masonry Pregrout | Passed | Ok to grout garage area masonry walls. | |
| 09/26/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 9-26-25: approved. | |
| 09/26/2025 | COT - RSEL - Electrical Final | Passed | 9-26-25: electrical final approved. | |
| 09/26/2025 | COT - RSEL - Grounding/Bonding | Passed | 9-26-25: grounding/bonding approved. | |
| 09/26/2025 | COT - RSEL - Outdoor Lighting | Passed | 9-26-25: outdoor lighting approved. | |
| 09/26/2025 | COT - RSME - Mechanical Final | Passed | 9-26-25: mechanical final approved. | |
| 09/26/2025 | RSBU - Building Final | Passed | 9-26-25: Building final approved. | |
| 09/26/2025 | COT - RSPL - Plumbing Final | Passed | 9-26-25: plumbing final approved. |