Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T20CM08404
Permit Details
Apply Date:
12/02/2020
Applicant:
Jesus Cedeno
Description:
ADDITION TO SFR & CARPORT
Permit Reviews
Permit Number - T20CM08404
Permit Status: Issued
Permit Description: ADDITION TO SFR & CARPORT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/05/2022 | REVISION - - 1ST | 08/31/2022 | COMPLETED |
08/16/2021 | REVISION - - 1ST | 09/20/2021 | COMPLETED |
12/02/2020 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 01/22/2021 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T20CM08404
Permit Status: Issued
Permit Description: ADDITION TO SFR & CARPORT
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
08/25/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
12/02/2020 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T20CM08404
Permit Status: Issued
Permit Description: ADDITION TO SFR & CARPORT
Date | Description | Comments |
---|---|---|
01/13/2021 | FUP T21OT00016 MUST BE PAID BEFORE FINAL INSPECTIONS. | |
01/13/2021 | FUP T21OT00016 MUST BE PAID BEFORE FINAL INSPECTIONS. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T20CM08404
Permite Description: ADDITION TO SFR & CARPORT
Total Outstanding Inspections - 5
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/04/2022 | COT - LCBU - Framing | N/A | Canceled | Inspection Canceled |
02/07/2024 | RSBU - Building Final | N/A | Re-inspection required | 2/7/24: receptacle under kitchen sink must be GFCI and must be properly installed (currently installed behind cabinet), Arc-fault breaker's missing at multiple locations, outdoor receptacle must be WR, water hammer arrestors missing at dishwasher and laundry room, anti-tip missing at range, kitchen sink and bathroom lavs all have drainage against code (interior must be smooth surface), A/C unit missing p-trap and condensate drain, bathroom and laundry room have been switched (plans must be submitted and show new location), toilets must be caulked. Insulate water lines at water heater. |
02/07/2024 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 2/7/24: receptacle under kitchen sink must be GFCI and must be properly installed (currently installed behind cabinet), Arc-fault breaker's missing at multiple locations, outdoor receptacle must be WR, water hammer arrestors missing at dishwasher and laundry room, anti-tip missing at range, kitchen sink and bathroom lavs all have drainage against code (interior must be smooth surface), A/C unit missing p-trap and condensate drain, bathroom and laundry room have been switched (plans must be submitted and show new location), toilets must be caulked. Insulate water lines at water heater. |
02/07/2024 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 2/7/24: receptacle under kitchen sink must be GFCI and must be properly installed (currently installed behind cabinet), Arc-fault breaker's missing at multiple locations, outdoor receptacle must be WR, water hammer arrestors missing at dishwasher and laundry room, anti-tip missing at range, kitchen sink and bathroom lavs all have drainage against code (interior must be smooth surface), A/C unit missing p-trap and condensate drain, bathroom and laundry room have been switched (plans must be submitted and show new location), toilets must be caulked. Insulate water lines at water heater. |
02/07/2024 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 2/7/24: receptacle under kitchen sink must be GFCI and must be properly installed (currently installed behind cabinet), Arc-fault breaker's missing at multiple locations, outdoor receptacle must be WR, water hammer arrestors missing at dishwasher and laundry room, anti-tip missing at range, kitchen sink and bathroom lavs all have drainage against code (interior must be smooth surface), A/C unit missing p-trap and condensate drain, bathroom and laundry room have been switched (plans must be submitted and show new location), toilets must be caulked. Insulate water lines at water heater. |
Completed Inspections
Permit Status: Issued
Permit Number: T20CM08404
Permit Description: ADDITION TO SFR & CARPORT
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/26/2021 | COT - RSBU - Preslab | Passed | {Activity date: 01/26/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - APPROVED} | |
01/26/2021 | COT - RSPL - Rough Soil | Passed | {Activity date: 01/26/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - APPROVED} | |
01/26/2021 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 01/26/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - APPROVED} | |
09/08/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed | Duplicate inspection 9/8/2023 | |
09/08/2023 | COT - RSBU - Interior Shear Bracing | Passed | N/A 9/8/2923 | |
11/06/2023 | COT - RSBU - Roof Nailing | Passed | Carport/patio cover columns,beams, rafters, and plywood sheathing is properly installed. 2x6 hangers and H2.5 clips are properly nailed into ledger/rafters and beam/rafters. okay to proceed with roofing material and stucco finish. | |
11/06/2023 | RSBU - Building Progress | Passed | Carport/patio cover columns,beams, rafters, and plywood sheathing is properly installed. 2x6 hangers and H2.5 clips are properly nailed into ledger/rafters and beam/rafters. okay to proceed with roofing material and stucco finish. | |
02/07/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
02/07/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
02/07/2024 | COT - RSPL - Yard Water Line | Passed | ||
03/08/2024 | RSBU - Building Final | Passed | ||
03/08/2024 | COT - RSEL - Electrical Final | Passed | ||
03/08/2024 | COT - RSME - Mechanical Final | Passed | ||
03/08/2024 | COT - RSPL - Plumbing Final | Passed |