Permit: T20CM08404

Parcel: 124081740


Addresses:

150 N HIGHLAND AV


Inspection Status: Canceled

Inspection History: COT - RSEL - Electrical Final 

Permit Number - T20CM08404

Inspection Description - COT - RSEL - Electrical Final 

Inspection Status - Canceled

Date Description Inspector Results Comments
11/04/2022 COT - RSEL - Electrical Final  Canceled Inspection Canceled
02/07/2024 COT - RSEL - Electrical Final  Re-inspection required 2/7/24: receptacle under kitchen sink must be GFCI and must be properly installed (currently installed behind cabinet), Arc-fault breaker's missing at multiple locations, outdoor receptacle must be WR, water hammer arrestors missing at dishwasher and laundry room, anti-tip missing at range, kitchen sink and bathroom lavs all have drainage against code (interior must be smooth surface), A/C unit missing p-trap and condensate drain, bathroom and laundry room have been switched (plans must be submitted and show new location), toilets must be caulked. Insulate water lines at water heater.
03/08/2024 COT - RSEL - Electrical Final  Passed