Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY ADDITION
Address NEW:
450 W CALLE MARGARITA
Apply Date:
09/03/2019
Applicant:
N/A
Description:
ADDITION AND REMOVATIONS TO SFR
Contractors:
  • QUIHUIS ARCHITECTURE CO LLC

Outstanding Activity Conditions

Permit Number - T19CM06379
Permit Status: Closed
Permit Description: ADDITION AND REMOVATIONS TO SFR
Total Outstanding Activity Conditions - 1
Date Name
09/03/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T19CM06379
Permite Description: ADDITION AND REMOVATIONS TO SFR
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
03/10/2020 BUILDING - FINAL N/A Denied 1- Shall provide the address on the the house.
03/10/2020 PLUMBING - FINAL N/A Denied 1- Shall provide a water hammer arrestor for the dishwasher water supply line.
2- Shall secure the Dishwasher drain hose to bottom of countertop with a approved strap.
3- Shall provide a hose bib vacuum breaker at rear HB.
4- Shall provide a sediment trap for the water heater gas supply.
5- Shall provide (3) sheet metal screws per joint on the water heater vent connector.
6- Shall provide a 1 inch annular space around the water heater double flu vent.
03/10/2020 MECHANICAL - FINAL N/A Denied 1- Shall provide a ladder for access to the roof .
2- Shall provide protection for the condensate drain.

Completed Inspections

Permit Status: Closed
Permit Number: T19CM06379
Permit Description: ADDITION AND REMOVATIONS TO SFR
Total Completed Inspections - 8
Date Description Inspector Results Comments
09/20/2019 EXCAVATION/LAYOUT REBAR & ZON TVALENCIA Approved
10/15/2019 REINFORCED MASONRY PRE-GROUT TVALENCIA Approved
11/04/2019 MECHANICAL - INTERMEDIATE TVALENCIA Approved
11/13/2019 RESIDENTIAL INTERMEDIATE TVALENCIA Approved
11/13/2019 FRAMING TVALENCIA Approved
01/10/2020 TEP CLEARANCE - PM WGALLAG1 Approved CODE INCR
01/10/2020 ELECTRIC - SERVICE UPGRADE WGALLAG1 Approved Ok for clearance INCR
03/10/2020 ELECTRIC - FINAL TVALENCIA Approved

Documents

File Name Document Type  
001_A1.1.TIF CONSTRPLANS VIEW
002_MP1.1.TIF CONSTRPLANS VIEW
003_E1.1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW