Permit: T19CM06379

Parcel: 138140570

Inspection Status: Approved

Inspection History: RESIDENTIAL INTERMEDIATE

Date Description Inspector Results Comments
11/13/2019 RESIDENTIAL INTERMEDIATE Approved
11/06/2019 RESIDENTIAL INTERMEDIATE Denied 1- Conductors not secured at front bedroom switch and switch in hallway entry.
11/04/2019 RESIDENTIAL INTERMEDIATE Denied 1- Loose conductors in the Hall Bathroom light switch.
2- Metal boxes in west bedroom not grounded.
3- Kitchen sanitary vent at top fur out missing a shielded plate.
10/18/2019 RESIDENTIAL INTERMEDIATE Denied 1- Shall provide 3 sided blocking on all forced air vents.
2- Soffit is incomplete
Horizontal vent for the Kitchen Sink shall rise 6 inches above the flood level rim of the fixture.
Shall provide a mission specialty coupling and remove the no horizontal b coupling underground.
3- Shall provide a water test on the DWV system.
4- Electric is incomplete.
5- Inspection stopped.
10/16/2019 RESIDENTIAL INTERMEDIATE Denied 1- Doors locked no access at the time of inspection request.