Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/13/2019 | FRAMING | Approved | ||
| 11/06/2019 | FRAMING | Denied | 1- Conductors not secured at front bedroom switch and switch in hallway entry. | |
| 11/04/2019 | FRAMING | Denied | 1- Loose conductors in the Hall Bathroom light switch. 2- Metal boxes in west bedroom not grounded. 3- Kitchen sanitary vent at top fur out missing a shielded plate. |
|
| 10/18/2019 | FRAMING | Denied | 1- Shall provide 3 sided blocking on all forced air vents. 2- Soffit is incomplete Horizontal vent for the Kitchen Sink shall rise 6 inches above the flood level rim of the fixture. Shall provide a mission specialty coupling and remove the no hub coupling underground. 3- Shall provide a water test on the DWV system. 4- Electric is incomplete. 5- Inspection stopped. |
|
| 10/16/2019 | FRAMING | Denied | 1- Doors locked no access at the time of inspection request. |