Permit: T19CM06379

Parcel: 138140570

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/10/2020 PLUMBING - FINAL Denied 1- Shall provide a water hammer arrestor for the dishwasher water supply line.
2- Shall secure the Dishwasher drain hose to bottom of countertop with a approved strap.
3- Shall provide a hose bib vacuum breaker at rear HB.
4- Shall provide a sediment trap for the water heater gas supply.
5- Shall provide (3) sheet metal screws per joint on the water heater vent connector.
6- Shall provide a 1 inch annular space around the water heater double flu vent.
03/06/2020 PLUMBING - FINAL Not ready for Inspection need to add elbow down on TPR valve on water heater