Permit: T19CM01870
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
1110 S MANN AV
Address NEW:
1110 S MANN AV
Apply Date:
03/15/2019
Applicant:
JOHNNY MERCHANT
Description:
BATHROOM ADDITION
Permit Reviews
Permit Number - T19CM01870
Permit Status: Expired
Permit Description: BATHROOM ADDITION
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/15/2019 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 03/15/2019 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T19CM01870
Permit Status: Expired
Permit Description: BATHROOM ADDITION
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/15/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T19CM01870
Permite Description: BATHROOM ADDITION
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2019 | COT - LCBU - Framing | N/A | Canceled | {Activity date: 08/20/2019; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } |
| 11/04/2022 | COT - RSME - Mechanical Final | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | RSBU - Building Final | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - RSPL - Plumbing Final | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - RSEL - Electrical Final | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM01870
Permit Description: BATHROOM ADDITION
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/05/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 07/05/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by VFLORES1 - } ; {Activity date: 06/17/2019; Status: Correction Required; Inspector: GWEST; Comment: Entered by DMERANZ1 - PVC water line not allowed under the new addition. Red clay sewer pipe has been decreased in size at new additional sewer connections installed. The red coat interior dia shall not be decreased for that section. Red Clay pipe is only allowed outside a building or its footings. Set backs were measured and are good.} |
|
| 07/26/2019 | COT - RSBU - Preslab | Passed | {Activity date: 07/26/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by VFLORES1 - } ; {Activity date: 07/23/2019; Status: Correction Required; Inspector: GWEST; Comment: Entered by DMERANZ1 - Building drainage piping can be sleeved and run perpendicular through a footing but cannot run parallel in the footing. No dimensions (width/depth) on footing detail or call out for reinforcing steel/rebar (Top /bottom or none) size and placement. Rebar being used to be 3" from any dirt at bottom and sides. Rebar shall have clearance between ABS drain piping and the rebar for aggregate and cement during the pour. } |
|
| 07/26/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 07/26/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by VFLORES1 - } ; {Activity date: 07/23/2019; Status: Correction Required; Inspector: GWEST; Comment: Entered by DMERANZ1 - Building drainage piping can be sleeved and run perpendicular through a footing but cannot run parallel in the footing. No dimensions (width/depth) on footing detail or call out for reinforcing steel/rebar (Top /bottom or none) size and placement. Rebar being used to be 3" from any dirt at bottom and sides. Rebar shall have clearance between ABS drain piping and the rebar for aggregate and cement during the pour. } |
|
| 08/20/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 08/20/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
| 08/22/2019 | COT - RSBU - Roof Nailing | Passed | {Activity date: 08/22/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/20/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Provide ladder for inspection.} | |
| 10/30/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 10/30/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/29/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Work not complete enough to inspect} |