Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Address:
1110 S MANN AV
Address NEW:
1110 S MANN AV
Apply Date:
03/15/2019
Applicant:
JOHNNY MERCHANT
Description:
BATHROOM ADDITION

Permit Reviews

Permit Number - T19CM01870
Permit Status: Expired
Permit Description: BATHROOM ADDITION
Start Date Submittal Complete Date Status  
03/15/2019 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 03/15/2019 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T19CM01870
Permit Status: Expired
Permit Description: BATHROOM ADDITION
Total Outstanding Activity Conditions - 1
Date Name
03/15/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T19CM01870
Permite Description: BATHROOM ADDITION
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
08/20/2019 COT - LCBU - Framing N/A Canceled {Activity date: 08/20/2019; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
11/04/2022 COT - RSME - Mechanical Final N/A Canceled Inspection Canceled
11/04/2022 RSBU - Building Final N/A Canceled Inspection Canceled
11/04/2022 COT - RSPL - Plumbing Final N/A Canceled Inspection Canceled
11/04/2022 COT - RSEL - Electrical Final N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Expired
Permit Number: T19CM01870
Permit Description: BATHROOM ADDITION
Total Completed Inspections - 6
Date Description Inspector Results Comments
07/05/2019 COT - RSPL - Rough Soil Passed {Activity date: 07/05/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by VFLORES1 - } ; {Activity date: 06/17/2019; Status: Correction Required; Inspector: GWEST; Comment: Entered by DMERANZ1 - PVC water line not allowed under the new addition.
Red clay sewer pipe has been decreased in size at new additional sewer connections installed. The red coat interior dia shall not be decreased for that section.
Red Clay pipe is only allowed outside a building or its footings.
Set backs were measured and are good.}
07/26/2019 COT - RSBU - Preslab Passed {Activity date: 07/26/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by VFLORES1 - } ; {Activity date: 07/23/2019; Status: Correction Required; Inspector: GWEST; Comment: Entered by DMERANZ1 - Building drainage piping can be sleeved and run perpendicular through a footing but cannot run parallel in the footing.

No dimensions (width/depth) on footing detail or call out for reinforcing steel/rebar (Top
/bottom or none) size and placement.

Rebar being used to be 3" from any dirt at bottom and sides.
Rebar shall have clearance between ABS drain piping and the rebar for aggregate and cement during the pour.
}
07/26/2019 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 07/26/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by VFLORES1 - } ; {Activity date: 07/23/2019; Status: Correction Required; Inspector: GWEST; Comment: Entered by DMERANZ1 - Building drainage piping can be sleeved and run perpendicular through a footing but cannot run parallel in the footing.

No dimensions (width/depth) on footing detail or call out for reinforcing steel/rebar (Top
/bottom or none) size and placement.

Rebar being used to be 3" from any dirt at bottom and sides.
Rebar shall have clearance between ABS drain piping and the rebar for aggregate and cement during the pour.
}
08/20/2019 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 08/20/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
08/22/2019 COT - RSBU - Roof Nailing Passed {Activity date: 08/22/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/20/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Provide ladder for inspection.}
10/30/2019 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 10/30/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/29/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Work not complete enough to inspect}

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW