Inspection Status: Passed
Inspection History: COT - RSPL - Rough Soil
| Date |
Description |
Inspector |
Results |
Comments |
| 07/05/2019 |
COT - RSPL - Rough Soil |
MRAMBER |
Approved |
Entered by VFLORES1 - |
| 06/17/2019 |
COT - RSPL - Rough Soil |
GWEST |
Correction Required |
Entered by DMERANZ1 - PVC water line not allowed under the new addition.
Red clay sewer pipe has been decreased in size at new additional sewer connections installed. The red coat interior dia shall not be decreased for that section.
Red Clay pipe is only allowed outside a building or its footings.
Set backs were measured and are good. |