Permit Details

Status:
Complete
Type:
Commercial Building
Address:
4984 E 22ND ST
Address NEW:
4984 E 22ND ST
Apply Date:
11/03/2017
Applicant:
Description:
TI: VET HOSPITAL: OK TO OCCUPY

Permit Reviews

Permit Number - T17CM08232
Permit Status: Complete
Permit Description: TI: VET HOSPITAL: OK TO OCCUPY
Start Date Submittal Complete Date Status  
05/07/2018 POST 3RD PARTY REVIEW 07/05/2018 COMPLETED Review Details
11/03/2017 PLANS OK TO SUBMIT - COMM 11/03/2017 COMPLETED Review Details
11/06/2017 3RD PARTY REVIEW - COMMERCIAL 05/07/2018 COMPLETED Review Details

Conditions

Permit Number - T17CM08232
Permit Status: Complete
Permit Description: TI: VET HOSPITAL: OK TO OCCUPY
Date Description Comments
11/03/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Complete
Permit Number: T17CM08232
Permite Description: TI: VET HOSPITAL: OK TO OCCUPY
Total Outstanding Inspections - 12
Last Inspection Date Description Inspector Results Comments
01/30/2019 COT - HCBU - Exterior Clips/Sheathing N/A Canceled {Activity date: 01/30/2019; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by CBELL1 - }
11/07/2022 COT - LCPL - Gas Pressure Test N/A Canceled Inspection Canceled
11/07/2022 COT - LCBU - Building Final N/A Canceled Inspection Canceled
11/07/2022 COT - LCEL - Electrical Intermediate N/A Canceled Inspection Canceled
11/07/2022 COT - LCBU - Framing N/A Canceled Inspection Canceled
11/07/2022 COT - LCME - Mechanical Above Ceiling N/A Canceled Inspection Canceled
11/07/2022 TRSP - ROW - Final/Close-Out N/A Canceled Inspection Canceled
11/07/2022 COT - LCEL - Electrical Above Ceiling N/A Canceled Inspection Canceled
11/07/2022 COT - LCME - Mechanical Intermediate N/A Canceled Inspection Canceled
11/07/2022 COT - LCBU - Building Progress N/A Canceled Inspection Canceled
11/07/2022 COT - LCPL - Medical Gas/Test N/A Canceled Inspection Canceled
12/27/2023 COT - HCPL - Medical Gas/Test N/A Not Applicable Not performed by building inspector, approved by the vendor who supplied medical gases.

Completed Inspections

Permit Status: Complete
Permit Number: T17CM08232
Permit Description: TI: VET HOSPITAL: OK TO OCCUPY
Total Completed Inspections - 34
Date Description Inspector Results Comments
08/28/2018 COT - LCEL - Grounding/Bonding Passed {Activity date: 08/28/2018; Status: Approved; Inspector: GWest; Comment: Entered by GWEST2 - 3/0 copper GEC connected to rebar in footing with DB/concrete encasement clamps}
09/17/2018 COT - LCPL - Rough Soil Passed {Activity date: 09/14/2018; Status: Denied; Inspector: BJONES; Comment: Entered by BJONES1 - NO WATER IN TEST PIPE} ; {Activity date: 09/17/2018; Status: Approved; Inspector: DQUINN; Comment: Entered by DQUINN1 - } ; {Activity date: 09/10/2018; Status: Partial Approval; Inspector: MHASSAN; Comment: Entered by CMURPHY1 - most of South Side okay appear to be missing couple of connections by food prep area okay to cover all but that area.} ; {Activity date: 09/07/2018; Status: Partial Approval; Inspector: MHASSAN; Comment: Entered by CMURPHY1 - F3 North or North half of building okay.}
03/18/2019 COT - LCPL - Sewer Passed {Activity date: 03/18/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by CBELL1 - ok to backfill}
03/18/2019 COT - LCPL - Backwater Valve Passed {Activity date: 03/18/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by CBELL1 - }
03/25/2019 COT - LCPL - Yard Water Line Passed {Activity date: 03/25/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by CBELL1 - }
04/08/2019 COT - LCPL - Medical Gas Preconstruction Mtg Passed {Activity date: 04/08/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by CBELL1 - }
05/15/2019 PDSD Building Division - TEP PM Clearance Passed {Activity date: 05/15/2019; Status: Approved; Inspector: GWEST; Comment: Entered by CBELL1 - CODE ECO}
05/15/2019 COT - LCEL - Construction Power Passed {Activity date: 05/15/2019; Status: Approved; Inspector: GWEST; Comment: Entered by CBELL1 - Ufers connected, Gas is bonded, Water is bonded. All sized in accordance with the NEC based on SE Cable size. Main bonding jumper is attached to the can.
TEP was called for Clearance on this new and separate Switch Gear. Spoke with Natalie, ECO.} ; {Activity date: 05/09/2019; Status: Correction Required; Inspector: GWEST; Comment: Entered by VFLORES1 - Install water bond and gas bond for TEP Clearance}
05/15/2019 COT - LCEL - Service Upgrade Passed {Activity date: 05/15/2019; Status: Approved; Inspector: GWEST; Comment: Entered by CBELL1 - Ufers connected, Gas is bonded, Water is bonded. All sized in accordance with the NEC based on SE Cable size. Main bonding jumper is attached to the can.} ; {Activity date: 05/09/2019; Status: Correction Required; Inspector: GWEST; Comment: Entered by VFLORES1 - Install water bond and gas bond for TEP Clearance}
10/01/2019 PDSD Site/Engineering Division - NPPO Passed {Activity date: 10/01/2019; Status: Approved; Inspector: RLEDONNE; Comment: Entered by DMERANZ1 - }
10/01/2019 PDSD Building Division - Sign Final Passed {Activity date: 10/01/2019; Status: Approved; Inspector: RLEDONNE; Comment: Entered by DMERANZ1 - }
12/04/2019 COT - LCEL - Electrical Underground Passed {Activity date: 12/04/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - } ; {Activity date: 10/03/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Phase one.} ; {Activity date: 03/14/2019; Status: Partial Approval; Inspector: BJONES; Comment: Entered by CBELL1 - 4- 4" Conduits to switch gear at building} ; {Activity date: 02/13/2019; Status: Partial Approval; Inspector: BJONES; Comment: Entered by CBELL1 - 50’ 4” pvc conduit includes 2 runs to TEP and 4 runs to distribution panels} ; {Activity date: 09/19/2018; Status: Partial Approval; Inspector: BJONES; Comment: Entered by CBELL1 - from grid H5 to south END of building} ; {Activity date: 09/20/2018; Status: Partial Approval; Inspector: GWEST; Comment: Entered by CBELL1 - Under conduit remainder of bldg} ; {Activity date: 01/08/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by CBELL1 - Under slab}
12/04/2019 COT - LCEL - Outdoor Lighting Passed {Activity date: 12/04/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - }
12/04/2019 COT - LCBU - Preslab Passed {Activity date: 12/04/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - } ; {Activity date: 10/08/2018; Status: Partial Approval; Inspector: GWest; Comment: Entered by GWEST2 - Approved South half pour} ; {Activity date: 10/01/2018; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by DQUINN1 - NORTH 1/2 OF BUILDING OK TO POUR}
12/04/2019 COT - LCPL - Plumbing Above Ceiling Passed {Activity date: 12/04/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - } ; {Activity date: 07/26/2019; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VFLORES1 - }
11/17/2020 COT - BULD - SWG Clearance Passed {Activity date: 11/17/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - CODE} ; {Activity date: 10/01/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - }
01/13/2021 COT - LCPL - Plumbing Intermediate Passed {Activity date: 01/13/2021; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - Partial. Phase 3, 2nd floor, rooms 203, 204, 205A, 209, bathrooms, lactation room.
} ; {Activity date: 11/17/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - Partial. Phase two all hard-lid areas ok.
} ; {Activity date: 11/16/2020; Status: Not ready for Inspection; Inspector: JBURGE; Comment: Entered by PAHUMAD1 - Not ready, Contractor cancelled.} ; {Activity date: 09/21/2020; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by JSCHNEI2 - pa
All 1st floor phase 2 potable and abs ok to cover.

} ; {Activity date: 07/16/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by JSCHNEI2 - Partial. All underground waste lines... ok to infill slab, phase two.} ; {Activity date: 02/27/2019; Status: Partial Approval; Inspector: BJONES; Comment: Entered by BSTEVENS - } ; {Activity date: 02/01/2019; Status: Partial Approval; Inspector: BJONES; Comment: Entered by CBELL1 - North and East Exterior Walls Only Rain leaders & 2 Patient rooms} ; {Activity date: 01/30/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by CBELL1 - All except DWV areas.}
01/20/2021 COT - LCBU - Building Above Ceiling Passed {Activity date: 01/20/2021; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - -AP} ; {Activity date: 11/17/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - Partial. Phase two all hard-lid areas ok.
} ; {Activity date: 12/04/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by ESTEVEN1 - PHASE ONE COMPLETE} ; {Activity date: 07/26/2019; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VFLORES1 - } ; {Activity date: 07/16/2019; Status: Not ready for Inspection; Inspector: GWEST; Comment: Entered by DMERANZ1 - Mark, Superintendent will call this in next week.
}
10/08/2021 COT - HCBU - Interior Shear Bracing Passed {Activity date: 10/08/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/09/2021; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Partial. Phase 3, lobby, second-floor hard lids and office area one side.} ; {Activity date: 01/26/2021; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - PARTIAL PHASE 3 SECOND FLOOR, INCLUDING HARD LID AREAS} ; {Activity date: 01/15/2021; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VLEON1 - PARTIAL, PHASE II COMPLETE, OK TO TAPE PROGRESS AREA} ; {Activity date: 12/03/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - Partial. Phase two... south half.} ; {Activity date: 03/11/2020; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by BSTEVENS - }
02/09/2022 COT - LCEL - Electrical Final Passed {Activity date: 02/09/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} ; {Activity date: 04/22/2021; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - PARTIAL APPROVAL FOR SECOND PHASE ONLY} ; {Activity date: 12/30/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - OK phase 1.} ; {Activity date: 12/10/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Inspection for phase 1 only, provide GFI protection where needed, restroom exhaust fans to run continuously during business hours.}
02/15/2022 COT - LCPL - Plumbing Final Passed {Activity date: 02/15/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP recommend issuing TCO upon correction of air balance report issue and approval of other inspections.

Duo 520-981-7697

Ready now

} ; {Activity date: 04/22/2021; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - PARTIAL APPROVAL FOR SECOND PHASE ONLY} ; {Activity date: 04/21/2021; Status: Partial Approval; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF WATER DISINFECTION REPORT FOR PHASE 2 COMPLETED} ; {Activity date: 02/21/2020; Status: Partial Approval; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - SPECIAL INSPECTION FOR MEDICAL GASES IS REQUIRED} ; {Activity date: 12/12/2019; Status: Partial Approval; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF THE WATER DISINFECTION REPORT COMPLETED} ; {Activity date: 12/10/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Inspection for phase 1 only,Provide sterilization report, provide med gas Nitrogen report, complete all inspections.}
02/24/2022 PDSD Site/Engineering Division - Landscaping Passed {Activity date: 02/24/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by VVERA1 - IS APPROVED} ; {Activity date: 02/22/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VVERA1 - CN/CONTRACTOR IS RESCHEDULING INSPECTION.
} ; {Activity date: 12/04/2019; Status: Partial Approval; Inspector: RLEDONNE; Comment: Entered by SFLORES2 - }
02/25/2022 COT - FCON - Alarm - Final Passed {Activity date: 02/25/2022; Status: Approved; Inspector: wmotto1; Comment: Entered by WMOTTO1 - } ; {Activity date: 02/24/2022; Status: Partial Approval; Inspector: MRoss; Comment: Entered by MROSS2 - -Phase 3-We tested the horns and strobes and all worked
-The duct detector on 2nd floor needs to be re-tested. It did not report to panel and did not shut down HVAC unit.} ; {Activity date: 04/28/2021; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - 1. Ok for TCO for Phase 2.
2. Phase 3 is next.} ; {Activity date: 02/03/2020; Status: Partial Approval; Inspector: MRoss; Comment: Entered by MROSS2 - OK for TCO in new addition to animal hospital.
-Add notification in 2nd floor locker room of addition

Alarm system will extend into existing side as tenant improvement is being done.}
02/25/2022 COT - FCON - Sprinkler - Final Passed {Activity date: 02/25/2022; Status: Approved; Inspector: wmotto1; Comment: Entered by WMOTTO1 - } ; {Activity date: 02/24/2022; Status: Cancelled; Inspector: MRoss; Comment: Entered by MROSS2 - Cancelled by contractor} ; {Activity date: 02/03/2020; Status: Partial Approval; Inspector: MRoss; Comment: Entered by MROSS2 - -Submit as-built plans to TFD} ; {Activity date: 03/05/2019; Status: Partial Approval; Inspector: MRoss; Comment: Entered by MROSS2 - Sprinkler OH & Hydro - Partial inspection 1 of 3. First floor only.

- Provide As-Built plans for changes to piping
-Verify allowable volume of concealed combustible areas
-Combustible stairs need to be covered with non combustible materials or have sprinkler coverage.}
02/25/2022 COT - FCON - Fire - Final Passed {Activity date: 02/25/2022; Status: Approved; Inspector: wmotto1; Comment: Entered by WMOTTO1 - } ; {Activity date: 02/03/2020; Status: Partial Approval; Inspector: MRoss; Comment: Entered by MROSS2 - OK for TCO of new addition to animal hospital
}
08/04/2022 COT - LCME - Mechanical Final Passed {Activity date: 08/04/2022; Status: Approved; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF AIR BALANCE REPORT COMPLETED} ; {Activity date: 04/11/2022; Status: Correction Required; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - THE MINIMUM EXHAUST FLOW RATE FOR ANIMAL HOLDING ROOMS (EF-2) IS 0.9 CFM PER SF} ; {Activity date: 02/10/2022; Status: Correction Required; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - EXHAUST FLOW RATES FOR EF-1 & EF-2 MORE THAN 10% BELOW REQUIREMENT} ; {Activity date: 02/09/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Partial. Pending air balance report for last phase.} ; {Activity date: 04/28/2021; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Partial, phase 2 mechanical complete.} ; {Activity date: 04/22/2021; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - PARTIAL APPROVAL FOR SECOND PHASE ONLY, 2 FURNACES REQIRE REROUTED EXHAUST PIPES IN SECOND STORY DOGHOUSE AREA} ; {Activity date: 12/23/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - Phase one} ; {Activity date: 12/11/2019; Status: Partial Approval; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF AIR BALANCE REPORT COMPLETED} ; {Activity date: 11/21/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Provide approved air balance report. Serviceable equipment on roof within 10 foot of roof edge must have guard rails. Line set insulation on roof must be coded for UV protection. Remove gooseneck From water heater exhaust, install per manufacture.}
12/27/2023 COT - HCBU - Building Final Passed 12/27/23: Project is complete, tenants are working out of building with a temporary certificate of occupancy. Okay to issue permanent certificate of occupancy for project.
12/27/2023 COT - HCBU - Building Progress Passed 12/27/23: Project is complete, tenants are working out of building with a temporary certificate of occupancy. Okay to issue permanent certificate of occupancy for project.
12/27/2023 COT - HCBU - Framing Passed 12/27/23: Project is complete, tenants are working out of building with a temporary certificate of occupancy. Okay to issue permanent certificate of occupancy for project.
12/27/2023 COT - HCEL - Electrical Above Ceiling Passed 12/27/23: Project is complete, tenants are working out of building with a temporary certificate of occupancy. Okay to issue permanent certificate of occupancy for project.
12/27/2023 COT - HCEL - Electrical Intermediate Passed 12/27/23: Project is complete, tenants are working out of building with a temporary certificate of occupancy. Okay to issue permanent certificate of occupancy for project.
12/27/2023 COT - HCME - Mechanical Above Ceiling Passed 12/27/23: Project is complete, tenants are working out of building with a temporary certificate of occupancy. Okay to issue permanent certificate of occupancy for project.
12/27/2023 COT - HCPL - Gas Pressure Test Passed 12/27/23: Project is complete, tenants are working out of building with a temporary certificate of occupancy. Okay to issue permanent certificate of occupancy for project.
12/27/2023 ENGR Engineering Final Passed

Documents

File Name Document Type  
T17CM08232 FINAL AIR BALANCE - DENIED1.PDF DOCUMENTS VIEW
T17CM08232 FINAL AIR BALANCE1.PDF DOCUMENTS VIEW
T17CM08232 PHASE 2 WATER REPORT1.PDF DOCUMENTS VIEW
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
T17CM08232 AIR BALANCE.PDF DOCUMENTS VIEW
T17CM08232 WATER REPORT.PDF DOCUMENTS VIEW
001_T1.0.TIF CONSTRPLANS VIEW
002_A0.1.TIF CONSTRPLANS VIEW
003_A0.2.TIF CONSTRPLANS VIEW
004_A0.3.TIF CONSTRPLANS VIEW
005_A1.0.TIF CONSTRPLANS VIEW
006_A1.1.1.TIF CONSTRPLANS VIEW
007_A1.1.2.TIF CONSTRPLANS VIEW
008_A1.1.3.TIF CONSTRPLANS VIEW
009_A1.2.1.TIF CONSTRPLANS VIEW
010_A1.2.2.TIF CONSTRPLANS VIEW
011_A1.2.3.TIF CONSTRPLANS VIEW
012_A1.2.4.TIF CONSTRPLANS VIEW
013_A1.3.1.TIF CONSTRPLANS VIEW
014_A1.3.2.TIF CONSTRPLANS VIEW
015_A1.3.3.TIF CONSTRPLANS VIEW
016_A1.3.4.TIF CONSTRPLANS VIEW
017_A1.3.5.TIF CONSTRPLANS VIEW
018_A1.3.6.TIF CONSTRPLANS VIEW
019_A1.3.7.TIF CONSTRPLANS VIEW
020_A1.4.1.TIF CONSTRPLANS VIEW
021_A1.4.2.TIF CONSTRPLANS VIEW
022_A1.4.3.TIF CONSTRPLANS VIEW
023_A1.4.4.TIF CONSTRPLANS VIEW
024_A5.0.TIF CONSTRPLANS VIEW
025_A5.1.TIF CONSTRPLANS VIEW
026_A6.0.TIF CONSTRPLANS VIEW
027_A6.1.TIF CONSTRPLANS VIEW
028_A6.2.TIF CONSTRPLANS VIEW
029_A7.0.TIF CONSTRPLANS VIEW
030_A7.1.TIF CONSTRPLANS VIEW
031_A7.2.TIF CONSTRPLANS VIEW
032_A7.3.TIF CONSTRPLANS VIEW
033_A7.4.TIF CONSTRPLANS VIEW
034_A7.5.TIF CONSTRPLANS VIEW
035_A7.6.TIF CONSTRPLANS VIEW
036_A7.7.TIF CONSTRPLANS VIEW
037_A7.8.TIF CONSTRPLANS VIEW
038_A7.9.TIF CONSTRPLANS VIEW
039_A8.0.TIF CONSTRPLANS VIEW
040_A8.1.TIF CONSTRPLANS VIEW
041_E1.0.TIF CONSTRPLANS VIEW
042_E1.1.TIF CONSTRPLANS VIEW
043_E1.2.TIF CONSTRPLANS VIEW
044_E1.3.TIF CONSTRPLANS VIEW
045_E2.0.TIF CONSTRPLANS VIEW
046_E2.1.TIF CONSTRPLANS VIEW
047_E2.2.TIF CONSTRPLANS VIEW
048_E3.0.TIF CONSTRPLANS VIEW
049_E3.1.TIF CONSTRPLANS VIEW
050_E3.2.TIF CONSTRPLANS VIEW
051_E4.0.TIF CONSTRPLANS VIEW
052_E5.0.TIF CONSTRPLANS VIEW
053_E6.0.TIF CONSTRPLANS VIEW
054_FA1.0.TIF CONSTRPLANS VIEW
055_FA1.1.TIF CONSTRPLANS VIEW
056_FA1.2.TIF CONSTRPLANS VIEW
057_M1.0.TIF CONSTRPLANS VIEW
058_M1.1.TIF CONSTRPLANS VIEW
059_M1.2.TIF CONSTRPLANS VIEW
060_M2.0.TIF CONSTRPLANS VIEW
061_M2.1.TIF CONSTRPLANS VIEW
062_M2.2.TIF CONSTRPLANS VIEW
063_M3.0.TIF CONSTRPLANS VIEW
064_M4.0.TIF CONSTRPLANS VIEW
065_M5.0.TIF CONSTRPLANS VIEW
066_MEP1.0.TIF CONSTRPLANS VIEW
067_MEP1.1.TIF CONSTRPLANS VIEW
068_P1.0.TIF CONSTRPLANS VIEW
069_P1.1.TIF CONSTRPLANS VIEW
070_P1.2.TIF CONSTRPLANS VIEW
071_P2.0.TIF CONSTRPLANS VIEW
072_P2.1.TIF CONSTRPLANS VIEW
073_P2.2.TIF CONSTRPLANS VIEW
074_P3.0.TIF CONSTRPLANS VIEW
075_P3.1.TIF CONSTRPLANS VIEW
076_P4.0.TIF CONSTRPLANS VIEW
077_P4.1.TIF CONSTRPLANS VIEW
078_P5.0.TIF CONSTRPLANS VIEW
079_P6.0.TIF CONSTRPLANS VIEW
080_P7.0.TIF CONSTRPLANS VIEW
081_P8.0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW