Permit Details

Status:
L of c
Type:
COMMERCIAL NEW
Address NEW:
1060 S HARRISON RD
Apply Date:
03/29/2017
Applicant:
CATALANO, VINCENT VICTOR
Description:
SHELL BUILDING WITH A PARTIAL SHELL
Architects:
  • CATALANO, VINCENT VICTOR
Contractors:
  • ALEXANDER BUILDING COMPANY INC

Permit Reviews

Permit Number - T17CM02466
Permit Status: L of c
Permit Description: SHELL BUILDING WITH A PARTIAL SHELL
Start Date Submittal Complete Date Status  
03/29/2017 PLANS OK TO SUBMIT - COMM 03/30/2017 COMPLETED Review Details
03/30/2017 COMMERCIAL - TI 05/04/2017 COMPLETED Review Details
05/11/2017 RESUBMITTAL - TI ALL 06/07/2017 COMPLETED Review Details
06/07/2017 RESUBMITTAL 06/20/2017 COMPLETED Review Details
06/20/2017 RESUBMITTAL 12/22/2017 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T17CM02466
Permit Status: L of c
Permit Description: SHELL BUILDING WITH A PARTIAL SHELL
Total Outstanding Activity Conditions - 1
Date Name
03/29/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: L of c
Permit Number: T17CM02466
Permit Description: SHELL BUILDING WITH A PARTIAL SHELL
Total Completed Inspections - 36
Date Description Inspector Results Comments
08/02/2017 ELECTRIC - UNDERGROUND mpugh1 Approved
08/02/2017 ELECTRIC - UFER mpugh1 Approved
08/02/2017 EXCAVATION/LAYOUT REBAR & ZON mpugh1 Approved
08/10/2017 PLUMBING - ROUGH, SOIL mpugh1 Approved un slab elec. - ok
08/17/2017 BUILDING PRE-SLAB MPUGH1 Approved IVRS - Inspection :*
09/08/2017 FRAMING MPUGH1 Approved IVRS - Inspection :*
09/08/2017 EXT METAL CLIPS/EXT SHEATHING MPUGH1 Approved IVRS - Inspection :*
09/11/2017 ROOF NAILING MPUGH1 Approved IVRS - Inspection :*
09/21/2017 STUCCO MESH mpugh1 Approved
10/02/2017 ELECTRIC - INTERMEDIATE mpugh1 Approved
10/02/2017 PLUMBING - INTERMEDIATE mpugh1 Approved
10/02/2017 MECHANICAL - INTERMEDIATE mpugh1 Approved
10/09/2017 PLUMBING - ABOVE CEILING RGREENE1 Approved
10/09/2017 SHEET ROCK NAILING RGREENE1 Approved
11/03/2017 ELECTRIC - ABOVE CEILING BBENEDO1 Approved IVRS - Inspection :*
11/29/2017 MECHANICAL - ABOVE CEILING BBENEDO1 Approved IVRS - Inspection :*
11/29/2017 ELECTRIC - PROGRESS BBENEDO1 Approved IVRS - Inspection :*
11/30/2017 TEP CLEARANCE - AM BBENEDON Approved ECO FOR HOUSE PANEL AND #110
12/04/2017 ENGINEERING - FINAL MRUSSO Approved
12/08/2017 ELECTRIC - FINAL RGREENE Approved
12/08/2017 FIRE - FINAL jdonovan Approved
12/11/2017 STEM WALL/RETAINING WALL RGREENE Approved
12/11/2017 BUILDING ABOVE CEILING RGREENE Approved
12/11/2017 U VALUE FOR WINDOW RGREENE Approved
12/11/2017 BUILDING - PROGRESS RGREENE Approved
12/11/2017 ELECTRIC - TEMPORARY SERVICE RGREENE Approved
12/11/2017 ELECTRIC - CONSTRUCTION POWER RGREENE Approved
12/11/2017 ELECTRIC - OUTDOOR LIGHTING RGREENE Approved
12/11/2017 OUTDOOR LIGHTING FINAL RGREENE Approved
12/11/2017 PLUMBING - YARD WTR LINE/TEST RGREENE Approved
12/11/2017 PLUMBING - SEWER HCS CONNECT RGREENE Approved
12/11/2017 SITE - SEWER RGREENE Approved
12/11/2017 PLUMBING - PROGRESS RGREENE Approved
12/11/2017 MECHANICAL - FINAL RGREENE1 Approved
12/11/2017 PLUMBING - FINAL RGREENE1 Approved
12/11/2017 BUILDING - FINAL RGREENE1 Approved