Permit Details

Status:
Expired
Type:
SIGN PERMIT
Address:
6959 E 22ND ST
Address NEW:
6959 E 22ND ST
Apply Date:
07/03/2012
Applicant:
ADDISIGNS
Description:
REMOVE 77 SQFT NONCONFORMING CABINET, RE-USE POLE, INSTALL 61.75 SQFT CABINET WITH ELECTRONIC MESSAGE CENTER (MESSAGE NOT TO CHANGE MORE THAN 1 X PER HOUR WITHOUT ANY ANIMATION) + CHANGE COPY ON 144 SQFT POLE SIGN FOR SHOPPING CENTER.
Contractors:
  • ADDISIGNS

Outstanding Activity Conditions

Permit Number - T12OT00993
Permit Status: Expired
Permit Description: REMOVE 77 SQFT NONCONFORMING CABINET, RE-USE POLE, INSTALL 61.75 SQFT CABINET WITH ELECTRONIC MESSAGE CENTER (MESSAGE NOT TO CHANGE MORE THAN 1 X PER HOUR WITHOUT ANY ANIMATION) + CHANGE COPY ON 144 SQFT POLE SIGN FOR SHOPPING CENTER.
Total Outstanding Activity Conditions - 2
Date Name
07/22/2013 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
07/22/2013 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T12OT00993
Permit Description: REMOVE 77 SQFT NONCONFORMING CABINET, RE-USE POLE, INSTALL 61.75 SQFT CABINET WITH ELECTRONIC MESSAGE CENTER (MESSAGE NOT TO CHANGE MORE THAN 1 X PER HOUR WITHOUT ANY ANIMATION) + CHANGE COPY ON 144 SQFT POLE SIGN FOR SHOPPING CENTER.
Total Completed Inspections - 3
Date Description Inspector Results Comments
11/20/2013 SIGN ELECTRIC DROBERTS Approved MET WITH RAY MAJUTA TO DISCUSS MY CONCERNS WITH THIS SITE. FOR THE SIGN INSTALLATION I HAVE CONCERNS IN THE FOLLOWING AREAS: 1) THE ORIGINAL SIGN PERMIT CALLS FOR BOLLARDS TO BE PLACED AT ALL CORNERS OF THE SIGN TO PREVENT ANY VEHICLES FROM BEING ABLE TO RUN INTO THE SIGN BASE. THESE HAVE NOT BEEN INSTALLED AT THIS TIME. ALSO THE STABILITY OF THE LOWER PORTION OF THE CABINET IS IN QUESTION. AT THIS TIME THERE IS ONLY ONE AREA WHERE THE LOWER STRUCTURE IS ATTACHED TO THE PAVEMENT BELOW THE STRUCTURE, OTHER AREAS HAVE BEEN DRILLED TO ACCEPT ADDITIONAL ATACHMENT BOLTS BUT THE BOLTS HAVE NOT BEEN INSTALLED. 2) ACCESS TO THE ELECTRICAL COMPONENTS IS WITHIN 6 INCHES OF THE OUTSIDE ODGE OF THE SIGNS AND MAYBE A HAZARD. ADDITIONAL PANELS MAYBE NEEDED ON EACH END OF THE CABINETS TO PREVENT EASY ACCESS TO ALL THE ELECTRICAL CABLES. 3) SOME OF THE WIRES ARE NOT SUPPORTED BETWEEN THE CABINETS, ADDITIONAL TIE DOWNS ARE NEEDED FOR WIRES THAT ARE OVER 3 FEET IN LENGTH. 4) PROVIDE DOCUMENTATION THAT VARIFY THAT ALL THE WIRING THAT IS EXPOSED IS RATED FOR EXTERIOR CONDITIONS.
THIS SIGN MAY NEED TO BE REVIEWED BY SOME ONE IN OUR STRUCTURAL SECTION SINCE SOME OF THESE CONCERNS DO NOT APPEAR TO BE COVERED BY PORTIONS OF THE N.E.C. CONTACT DAVID ROBERTS AT 349-7643 FOR FURTHER CLARIFICATION ON THE ISSUES AT THIS SITE. YOU MAY ALSO DISCUSS THESE ISSUES WITH RAY MAJUTA TO DETERMINE WHAT MIGHT BE NEEDED TO CLOSE OUT THIS PERMIT.
11/21/2013 SIGN INSPECTION DROBERTS Approved MET WITH STACE AND ADDRESSED MY CONCERNS WITH THIS SITE AND HAVE ASKED HIM TOO HAVE SOMEONE CONTACT ME SO THAT THIS WORK CAN BE COMPLETED AND THE PERMIT CLOSED.
08/12/2014 SIGN SITE REVIEW DROBERTS Approved

Documents

File Name Document Type  
None SIGNS VIEW