Inspection History Details
Inspection Status: Approved
Inspection History: SIGN ELECTRIC
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2014 | SIGN ELECTRIC | Approved | ||
| 03/04/2014 | SIGN ELECTRIC | Partial Approval | SOME OF THE COMMENTS FROM THE PREVIOUS INSPECTION HAVE NOT BEEN SUFFICIENTLY ADDRESSED AT THIS TIME: (1,3, AND 4). MAKE THE NECESSARY CORRECTIONS AS NEEDED PRIOR TO CALLING IN FOR ANOTHER INSPECTION. | |
| 11/20/2013 | SIGN ELECTRIC | Partial Approval | MET WITH RAY MAJUTA TO DISCUSS MY CONCERNS WITH THIS SITE. FOR THE SIGN INSTALLATION I HAVE CONCERNS IN THE FOLLOWING AREAS: 1) THE ORIGINAL SIGN PERMIT CALLS FOR BOLLARDS TO BE PLACED AT ALL CORNERS OF THE SIGN TO PREVENT ANY VEHICLES FROM BEING ABLE TO RUN INTO THE SIGN BASE. THESE HAVE NOT BEEN INSTALLED AT THIS TIME. ALSO THE STABILITY OF THE LOWER PORTION OF THE CABINET IS IN QUESTION. AT THIS TIME THERE IS ONLY ONE AREA WHERE THE LOWER STRUCTURE IS ATTACHED TO THE PAVEMENT BELOW THE STRUCTURE, OTHER AREAS HAVE BEEN DRILLED TO ACCEPT ADDITIONAL ATACHMENT BOLTS BUT THE BOLTS HAVE NOT BEEN INSTALLED. 2) ACCESS TO THE ELECTRICAL COMPONENTS IS WITHIN 6 INCHES OF THE OUTSIDE ODGE OF THE SIGNS AND MAYBE A HAZARD. ADDITIONAL PANELS MAYBE NEEDED ON EACH END OF THE CABINETS TO PREVENT EASY ACCESS TO ALL THE ELECTRICAL CABLES. 3) SOME OF THE WIRES ARE NOT SUPPORTED BETWEEN THE CABINETS, ADDITIONAL TIE DOWNS ARE NEEDED FOR WIRES THAT ARE OVER 3 FEET IN LENGTH. 4) PROVIDE DOCUMENTATION THAT VARIFY THAT ALL THE WIRING THAT IS EXPOSED IS RATED FOR EXTERIOR CONDITIONS. THIS SIGN MAY NEED TO BE REVIEWED BY SOME ONE IN OUR STRUCTURAL SECTION SINCE SOME OF THESE CONCERNS DO NOT APPEAR TO BE COVERED BY PORTIONS OF THE N.E.C. CONTACT DAVID ROBERTS AT 349-7643 FOR FURTHER CLARIFICATION ON THE ISSUES AT THIS SITE. YOU MAY ALSO DISCUSS THESE ISSUES WITH RAY MAJUTA TO DETERMINE WHAT MIGHT BE NEEDED TO CLOSE OUT THIS PERMIT. |
|
| 11/13/2013 | SIGN ELECTRIC | Partial Approval | I PHOTOGRAPHED THE SITE SO THAT I CAN DISCUSS MY CONCERNS WITH RAY MAJUTA. | |
| 11/07/2013 | SIGN ELECTRIC | Partial Approval | THE SIGN ELECTRIC APPEARS TO BE INCOMPLETE AT THIS TIME. I WILL VERIFY FULLY WITH RAY MAJUTA DOWNTOWN ABOUT WHAT ITEMS OF THE ELECTRICAL CODE ARE STILL NEEDED. CURRENTLY ALL OF THE EXTERNAL WIRES ARE NOT FULLY SUPPORTED AND MAY NEED TO BE ATTACHED TOO THE CABINETS IN SOME MANNER. THE CONTRACTOR HAS ADVISED ME THAT IN CERTAIN PORTIONS OF THE EMC CABINETS THAT ARE NOT ABLE TO USE SCREWS TO ATTACH CABLE RESTRAINTS/ SUPPORTS. I HAVE PHOTOGRAPHED THE INSIDE OF THE SIGN AND WILL PROVIDE RECOMMENDATIONS IN DETAIL IN MY NEXT POSTING. ALSO AREAS OF THE ELECTRICAL WIRING ARE IN AN EXPOSED MANNER WITHIN REACH OF PEDESTRIANS, THESE AREAS MAY NEED TO BE BLOCKED TO PREVENT ACCESS. | |
| 09/12/2013 | SIGN ELECTRIC | Partial Approval | REVISED DRAWINGS WERE PROVIDED AND APPROVED 9/12/13 AND SENT TO RECORDS. CALL FOR ELECTRIC INSPECTION, TURN IN SPECIAL INSPECTION SHEET. | |
| 09/10/2013 | SIGN ELECTRIC | Continued | Revision emailed in for review. D. Roberts conducted field inspection to confirm measurements concurrent with review of revision on height. | |
| 08/06/2013 | SIGN ELECTRIC | Correction Required | Field inspection done indicates 18" difference between bottom of street curb and grade at leading edge of sign. Revision to be done to plan. | |
| 07/22/2013 | SIGN ELECTRIC | Continued | Revisions all approved. Call in for electrical inspection when ready. | |
| 07/19/2013 | SIGN ELECTRIC | Continued | Additional information submitted to staff by contractor - review continues. | |
| 06/13/2013 | SIGN ELECTRIC | Continued | ADDITIONAL REVISION SUBMITTED 6/13 BY EMAIL. REVIEW CONTINUES. | |
| 06/03/2013 | SIGN ELECTRIC | Continued | Revision to the plans submitted after meeting with contractor and Ace Hardware owner on 5/28. Plans under review to proposed reconfiguration of sign cabinets on existing pole. | |
| 05/13/2013 | SIGN ELECTRIC | Denied | SIGN HEIGHT HAS GREATLY EXCEEDED THE APPROVED PLANS. THE MAX HEIGHT IS 12' TALL AS MEASURED FROM ROADWAY GRADE. THE SIGN HAS BEEN INSPECTED PER A COMPLAINT RECEIVED AND IT IS 18' TALL AS MEASURED FROM ROADWAY AND 16.5' TALL AS MEASURED FROM SIGN BASE. NO INSPECTIONS CAN BE CALLED IN ON THIS UNTIL IT HAS BEEN CORRECTED. NOTE ALSO - THE ELECTRONIC MESSAGE CENTER CAN CHANGE A MAX 1 X PER HOUR AND HAS BEEN SEEN BY THE INSPECTOR AS CHANGING 3 X IN 5 MINUTES. REQUIRES CORRECTION. |