Inspection Status: Approved
Inspection History: SIGN INSPECTION
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2014 | SIGN INSPECTION | Approved | ||
| 03/04/2014 | SIGN INSPECTION | Partial Approval | SEE PREVIOUS COMMENTS #1, #3, #4 FOR CORRECTIVE ACTIONS THAT NEED TO BE COMPLETED. | |
| 11/21/2013 | SIGN INSPECTION | Partial Approval | MET WITH STACE AND ADDRESSED MY CONCERNS WITH THIS SITE AND HAVE ASKED HIM TOO HAVE SOMEONE CONTACT ME SO THAT THIS WORK CAN BE COMPLETED AND THE PERMIT CLOSED. | |
| 11/20/2013 | SIGN INSPECTION | Partial Approval | MET WITH RAY MAJUTA TO DISCUSS MY CONCERNS WITH THIS SITE. FOR THE SIGN INSTALLATION I HAVE CONCERNS IN THE FOLLOWING TWO AREAS: 1) THE ORIGINAL SIGN PERMIT CALLS FOR BOLLARDS TO BE PLACED AT ALL CORNERS OF THE SIGN TO PREVENT ANY VEHICLES FROM BEING ABLE TO RUN INTO THE SIGN BASE. THESE HAVE NOT BEEN INSTALLED AT THIS TIME. ALSO THE STABILITY OF THE LOWER PORTION OF THE CABINET IS IN QUESTION AT THIS TIME. THERE IS ONLY ONE AREA WHERE THE LOWER STRUCTURE IS ATTACHED TO THE PAVEMENT BELOW THE STRUCTURE, OTHER AREAS HAVE BEEN DRILLED TO ACCEPT ADDITIONAL ATACHMENT LOCATIONS BUT THE BOLTS HAVE NOT BEEN INSTALLED. 2) ACCESS TO THE ELECTRICAL COMPONENTS IS WITHIN 6 INCHES OF THE OUTSIDE ODGE OF THE SIGNS AND MAYBE A HAZARD. ADDITIONAL PANELS MAYBE NEEDED ON EACH END OF THE CABINETS TO PREVENT EASY ACCESS TO ALL THE ELECTRICAL CABLES. 3) SOME OF THE WIRES ARE NOT SUPPORTED BETWEEN THE CABINETS, ADDITIONAL TIE DOWNS ARE NEEDED FOR WIRES THAT ARE OVER 3 FEET IN LENGTH. 4) PROVIDE DOCUMENTATION THAT VARIFY THAT ALL THE WIRING THAT IS EXPOSED IS RATED FOR EXTERIOR CONDITIONS. tHIS SIGN MAY NEED TO BE REVIEWED BY SOME ONE IN OUR STRUCTURAL SECTION SINCE SOME OF THESE CONCERNS DO NOT APPEAR TO BE COVERED BY PORTIONS OF THE N.E.C. CONTACT DAVID ROBERTS AT 349-7643 FOR FURTHER CLARIFICATION ON THE ISSUES AT THIS SITE. YOU MAY ALSO DISCUSS THESE ISSUES WITH RAY MAJUTA TO DETERMINE WHAT MIGHT BE NEEDED TO CLOSE OUT THIS PERMIT. |
|
| 11/13/2013 | SIGN INSPECTION | Partial Approval | I PHOTOGRAPHED THE SITE SO THAT I CAN DISCUSS MY CONCERNS WITH RAY MAJUTA. | |
| 11/07/2013 | SIGN INSPECTION | Partial Approval | THE SIGN IS NOT COMPLETE AT THIS TIME. SOME OF THE ELECTRICAL WIRES ARE UNPROTECTED AND WITHIN REACH OF PEDESTRIANS PASSING THROUGH THE AREA. THIS IS BEING ALLOWED SINCE THE INTERNAL ACCESS OF THE SIGN IS ONLY BLOCKED ON THE LOWER THIRD OF THE SIGNS. I WILL VERIFY IN THE CODE WHAT CORRECTIVE ACTIONS ARE NEEDED TO ENSURE THE SAFETY OF THE GENERAL PUBLIC IN THIS AREA. ALSO THE BOLLARDS THAT ARE SHOWN ON THE APPROVED DIAGRAHMS HAVE NOT BEEN INSTALLED AT THIS TIME. CORRECT ALL THESE ITEMS THAT ARE ATTACHED TO THE SIGN AND ELECTRICAL INSPECTION COMMENTS PRIOR TO SCHEDULING ANOTHER INSPECTION. | |
| 09/12/2013 | SIGN INSPECTION | Partial Approval | REVISED DRAWINGS WERE PROVIDED AND APPROVED 9/12/13 AND SENT TO RECORDS. CALL FOR ELECTRIC INSPECTION, TURN IN SPECIAL INSPECTION SHEET. | |
| 09/10/2013 | SIGN INSPECTION | Continued | REVISION SENT IN FOR REVIEW. FIELD INSPECTION DONE CONCURRENTLY TO CHECK DIMENSIONS/HEIGHT. | |
| 07/22/2013 | SIGN INSPECTION | Continued | CONTRACTOR'S REVISED PLANS ARE APPROVED. REQUIRES ELECTRICAL APPROVAL. DO NOT FINAL UNTIL SPECIAL INSPECTIONS DONE AND CERTIFICATE RETURNED TO SIGNS STAFF. | |
| 05/13/2013 | SIGN INSPECTION | Denied | SIGN HEIGHT HAS GREATLY EXCEEDED THE APPROVED PLANS. THE MAX HEIGHT IS 12' TALL AS MEASURED FROM ROADWAY GRADE. THE SIGN HAS BEEN INSPECTED PER A COMPLAINT RECEIVED AND IT IS 18' TALL AS MEASURED FROM ROADWAY AND 16.5' TALL AS MEASURED FROM SIGN BASE. NO INSPECTIONS CAN BE CALLED IN ON THIS UNTIL IT HAS BEEN CORRECTED. NOTE ALSO - THE ELECTRONIC MESSAGE CENTER CAN CHANGE A MAX 1 X PER HOUR AND HAS BEEN SEEN BY THE INSPECTOR AS CHANGING 3 X IN 5 MINUTES. REQUIRES CORRECTION. |