Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
04/03/2012
Applicant:
OGAS ANDREW
Description:
TI: 45,800 S.F. OFFICE
Contractors:
  • CONCORD GENERAL CONTRACTING INC

Permit Reviews

Permit Number - T12CM01566
Permit Status: C of o
Permit Description: TI: 45,800 S.F. OFFICE
Start Date Submittal Complete Date Status  
04/03/2012 PLANS OK TO SUBMIT - COMM 04/09/2012 COMPLETED Review Details
04/09/2012 COMMERCIAL - TI 04/26/2012 COMPLETED Review Details
04/26/2012 RESUBMITTAL 05/09/2012 COMPLETED Review Details
05/09/2012 RESUBMITTAL 05/31/2012 COMPLETED Review Details
05/31/2012 RESUBMITTAL 06/04/2012 COMPLETED Review Details
07/05/2012 REVISION - - 1ST 07/26/2012 COMPLETED Review Details
08/06/2012 REVISION - - 1ST 08/08/2012 COMPLETED Review Details
11/06/2012 REVISION - - 2ND 11/13/2012 COMPLETED Review Details
11/15/2012 REVISION - - 3RD 11/28/2012 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T12CM01566
Permit Status: C of o
Permit Description: TI: 45,800 S.F. OFFICE
Total Outstanding Activity Conditions - 1
Date Name
04/03/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T12CM01566
Permit Description: TI: 45,800 S.F. OFFICE
Total Completed Inspections - 37
Date Description Inspector Results Comments
06/14/2012 REINFORCED MASONRY PRE-GROUT MRAMBER Approved IVRS - Inspection :*
BLOCK OUT AS CL.1 BETWEEN R&Q
OK TO GROUT
09/17/2012 ELECTRIC - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
09/21/2012 FIRE - ALARM FINAL CBASALDU Approved 1. Phase 1 complete.
10/05/2012 BUILDING - PROGRESS MRAMBER Approved WEST OFFICES AND NORTH WALL 2ND PHASE FRAMING OK, OK OK TO SHEET ROCK THESE AREAS.
10/23/2012 PLUMBING - PRE SLAB JBURGE Approved IVRS - Inspection :*
10/23/2012 ELECTRIC - UNDERGROUND JBURGE Approved IVRS - Inspection :*
10/26/2012 FRAMING JBURGE Approved RESULT HAD BEEN ISSUED AS APPROVED. RE-OPEN AS PARTIAL
11/02/2012 PLUMBING - ROUGH, SOIL MRAMBER Approved EAST AND WEST OF CL. P. BETWEEN P.4-P.5
11/06/2012 BUILDING PRE-SLAB MRAMBER Approved 1) CL"P" WEST OK
2) BULLPEN "Z"- LP ROUND SUPPLY DUCT OK TO INSULATE
11/09/2012 PLUMBING - ABOVE CEILING RMYERS Approved
11/09/2012 PLUMBING - INTERMEDIATE RMYERS Approved
11/09/2012 SITE - SEWER RMYERS Approved 1. ROOMS 507 AND 509 OK TO ROCK. SHEETROCK IN ROOM 508 OK. SEWER CONNECTIONS OK-NEED TO SEE 2' CONTINUATION.
12/04/2012 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
12/11/2012 ELECTRIC - PROGRESS DSANTACR Approved IVRS - Inspection :*
12/11/2012 SHEET ROCK NAILING DSANTACR Approved IVRS - Inspection :*
12/28/2012 FIRE SPKLR - FINAL CBASALDU Approved need to add heads in hallway next to bathrooms
2. need as builds
12/28/2012 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
12/28/2012 ELECTRIC - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
12/28/2012 BUILDING ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
03/20/2013 RIGHT OF WAY - FINAL MCASTRO Approved
03/20/2013 PLUMBING - FINAL MRAMBER Approved IVRS - Inspection :*
03/20/2013 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
03/20/2013 PLUMBING - FINAL MRAMBER Approved IVRS - Inspection :*
03/21/2013 NPPO - FINAL RLEDONNE Approved
03/21/2013 SIGN - FINAL RLEDONNE Approved
03/21/2013 LANDSCAPE - FINAL RLEDONNE Approved
03/21/2013 ENGINEERING - FINAL RLEDONNE Approved
03/22/2013 ELECTRIC - FINAL MRAMBER Approved IVRS - Inspection :*
03/22/2013 BUILDING - FINAL MRAMBER Approved IVRS - Inspection :*
03/26/2013 FIRE - FINAL CSCHULTZ Approved
03/27/2013 EXT METAL CLIPS/EXT SHEATHING MRAMBER Approved
03/27/2013 ELECTRIC - UFER MRAMBER Approved
03/27/2013 ELECTRIC - TEMPORARY SERVICE MRAMBER Approved
03/27/2013 PLUMBING - PROGRESS MRAMBER Approved
03/27/2013 PLUMBING - GAS PRESS TEST FNL MRAMBER Approved
03/27/2013 PLUMBING - GAS PRESSURE TEST MRAMBER Approved
03/27/2013 MECHANICAL - HYDRONIC PIPING MRAMBER Approved

Documents

File Name Document Type  
None CERT OF OCC VIEW