Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Address:
565 E WETMORE RD
Apply Date:
08/29/2011
Applicant:
N/A
Description:
TI; RESTAURANT
Contractors:
  • J D I DEVELOPMENT LLC

Permit Reviews

Permit Number - T11CM02798
Permit Status: Expired
Permit Description: TI; RESTAURANT
Start Date Submittal Complete Date Status  
08/29/2011 COMMERCIAL - TI 09/07/2011 COMPLETED Review Details
09/07/2011 RESUBMITTAL 09/09/2011 COMPLETED Review Details
09/09/2011 RESUBMITTAL 09/13/2011 COMPLETED Review Details
09/19/2011 REVISION - - 1ST 09/19/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM02798
Permit Status: Expired
Permit Description: TI; RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
08/29/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11CM02798
Permite Description: TI; RESTAURANT
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
BUILDING - FINAL N/A Not Inspected
12/20/2011 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1) SEE NOTE #2 FROM 10/27/11
2) INDIRECT WASTE PIPING TO BE APPROVED TYPE, PROPERLY JOINED, ADEQUATELY SUPPORTED AND GRAVITY TYPE

Completed Inspections

Permit Status: Expired
Permit Number: T11CM02798
Permit Description: TI; RESTAURANT
Total Completed Inspections - 9
Date Description Inspector Results Comments
09/22/2011 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
09/29/2011 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
09/29/2011 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
11/09/2011 FRAMING AQUIROZ Approved
11/09/2011 FRAMING AQUIROZ Approved IVRS - Inspection :*
11/09/2011 FIRE - FINAL DSIWARSKI Approved
11/15/2011 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) FIXTURE GROUNDS ADDED-APPEARS NO EFFECTIVE GROUND FAULT PATH-NEED INSTRUCTIONS
2) THHN IS NOT AN APPROVED SUPPORT METHOD
3) FINISH PREVIOUS ITEMS 1, 4, 5 AND 6 (3 & 4)
4) SUPPORT BOXES
5) PLEASE PAY REINSPECTION FEE BEFORE NEXT INSPECTION
11/15/2011 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
12/20/2011 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
1) LETTER FOR GROUNDING IS NOT SUFFICIENT TO VERIFY EFFECTIVE GROUND FAULT PATH, NEED U.L. REQUIRED INSTRUCTIONS OR NRTL FIELD INSPECTION
2) NEED SIGN PERMIT AND PLANS ON SITE TO VERIFY CANOPIES

Documents

File Name Document Type  
001_A-001.TIF CONSTRPLANS VIEW
002_A-101.TIF CONSTRPLANS VIEW
003_A-102.TIF CONSTRPLANS VIEW
004_A-103.TIF CONSTRPLANS VIEW
005_A-104.TIF CONSTRPLANS VIEW
006_A-201.TIF CONSTRPLANS VIEW
007_A-301.TIF CONSTRPLANS VIEW
008_A-302.TIF CONSTRPLANS VIEW
009_A-303.TIF CONSTRPLANS VIEW
010_A-304.TIF CONSTRPLANS VIEW
011_A-401.TIF CONSTRPLANS VIEW
012_A-501.TIF CONSTRPLANS VIEW
013_A-502.TIF CONSTRPLANS VIEW
014_A-601.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW