Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T11BU01549
Permit Details
Apply Date:
11/22/2011
Applicant:
KIMLEY-HORN
Description:
GRADING
Contractors:
- SLETTEN CONSTRUCTION COMPANY ,
Permit Reviews
Permit Number - T11BU01549
Permit Status: Final
Permit Description: GRADING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/22/2012 | RESUBMITTAL - GRADING ALL | 08/14/2012 | COMPLETED |
| 11/14/2012 | REVISION - GRADING | 11/14/2012 | ACTIVE |
| 11/22/2011 | GRADING | 11/22/2011 | COMPLETED |
| 11/22/2011 | GRADING | 02/22/2012 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T11BU01549
Permit Status: Final
Permit Description: GRADING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/22/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T11BU01549
Permit Description: GRADING
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2012 | ENGINEERING PRE-CONSTRUCTION | MRUSSO | Approved | 1) MET WITH SUPERINTENDENT AND CONTRACTORS ON SITE. DISCUSSED SWPPP REQ. AND THE APPROVED GRADING PLAN. 2) THE STORM WATER PLAN HAS BEEN IMPLEMENTED AND SEDIMENT CONTROLS ARE IN PLACE FOR THE CURRENT DEMO WORK BEING DONE. 3) THE AZPDES AUTHORIZATION NUMBER/NOI HAS BEEN POSTED. 4) INSTALL A CONCRETE/MATERIALS WASH OUT WHEN NEEDED. 5) SWEEP UP TRACKING DAILY. 6) PERFORM AND DOCUMENT ALL STORM WATER SELF INSPECTIONS PER YOUR SWPPP. LAUREN MANKUS - ENG REVIEWER FOR THE CITY OF TUCSON. |
| 10/19/2012 | STORMWATER INSTALL OF CONTROLS | MRUSSO | Approved | 1) WALKED SITE WITH SUPERINTENDENT. CONTRACTOR OVER EXCAVATING THE BLDG PAD. 2) PERIMETER SEDIEMNT CONTROLS ARE IN PLACE 3) INSTALL A CONCRETE/MATERIALS WASH OUT WHEN NEEDED 4) PERFORM STORM WATER SELF INSPECTIONS PER YOUR SWPPP AND DOCUMENT THEM 5) CALL FOR INSPE FOR ANY CONCERNS OR STORM PIPE/CATCH BASIN CONSTRUCTION |
| 12/06/2012 | GRADING - TIER REV | MRUSSO | Approved | CHANGE IN APPROVED PLANS, STORM WATER WILL BE RETAINED ON SITE IN A UNDERGROUD BASIN 96" X 270 ' NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME |
| 12/12/2012 | GRADING - INTERMEDIATE | MRUSSO | Approved | GRADING PLAN HAS BEEN REVISED TO SHOW AN UNDERGROUND RET/DET BASIN ALONG THE FRONT OF THE BLDG. THIS BASIN WHEN FULL WILL PUMP INTO A 70' DRY WELL. ENSURE THE DRY WELL IS REGISTERED WITH ADEQ NO STORM WATER CONCERNS AT THIS TIME |
| 12/20/2012 | STORMWATER FOLLOW-UP INSP | MRUSSO | Approved | NO SIGNIFICANT CONCERNS AT THIS TIME |
| 04/15/2013 | STORMWATER FINAL INSPECTION | MRUSSO | Approved | |
| 07/03/2013 | LANDSCAPE INSPECTION | MRUSSO | Approved | |
| 07/03/2013 | GRADING - FINAL | MRUSSO | Approved |