Permit Details

Status:
Final
Type:
MULTI FAMILY ALTERATION
Address:
801 N SWAN RD
Apply Date:
08/27/2010
Applicant:
N/A
Description:
REPAIRS:GENERAL T10DV05668
Contractors:
  • B K STERLING L L C

Permit Reviews

Permit Number - T10CM02384
Permit Status: Final
Permit Description: REPAIRS:GENERAL T10DV05668
Start Date Submittal Complete Date Status  
08/27/2010 COMMERCIAL TI 10/05/2010 COMPLETED Review Details
10/05/2010 OTHER 10/07/2010 COMPLETED Review Details
10/26/2010 REVISION - - 1ST 11/08/2010 COMPLETED Review Details
11/08/2010 REVISION - - 1ST 11/30/2010 COMPLETED Review Details
11/30/2010 REVISION - - 2ND 12/01/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM02384
Permit Status: Final
Permit Description: REPAIRS:GENERAL T10DV05668
Total Outstanding Activity Conditions - 1
Date Name
08/27/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T10CM02384
Permit Description: REPAIRS:GENERAL T10DV05668
Total Completed Inspections - 13
Date Description Inspector Results Comments
12/08/2010 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
12/27/2010 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) LEAK BEHIND TUB
2) T & P DRAIN NOT SIZED PROPERLY SECURE DIVERTERS
3) SEPERATE STOPS REQUIRED
4) INSTALL ISOLATION SUPPORTS AT TOP PLATE PENETRATIONS
5) INSTALL HB VAC BREAKER
6) INSTALL TRAP PRIMER AT FD
12/27/2010 ELECTRIC - INTERMEDIATE RMORENO Approved IVRS - Inspection :
See detailed listing on site.| 999*
801 N. SWAN RD:
1) RISER TO SERVICE TO BE RE-STRAPPED, ANCHORED TO WALL
2) FEEDER TO SUB PANEL MISSING CONNECTOR
3) 1/2 OUTLET EMT MISSING STRAPPING BOX TO BE ANCHORED
803 N. SWAN RD:
1) FEEDER TO SUB PANEL MISSING CONNECTOR
2) 1/2 OUTLET EMT MISSING STRAPPING AND BOX TO BE ANCHORED
805 N. SWAN RD:
1) FEEDER TO SUB PANEL MISSING CONNECTOR
2) 1/2 OUTLET EMT MISSING STRAPPING AND BOX TO BE ANCHORED
3) REMOVE WIRE AND BOXES NOT BEING USED
12/27/2010 BUILDING ABOVE CEILING GDABBS Approved IVRS - Inspection :*
12/27/2010 FRAMING GDABBS Approved IVRS - Inspection :*
12/30/2010 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE 2" DUCT LINER OR ROOF TOP DUCT (R-8), PROVIDE R-8 ON ALL DUCT IN ATTIC SPACE
2) CEILING DIFFUSERS ARE TO BE FRAMED ON 3 SIDES
3) ALL PVC PIPE IS TO BE PRIMERED AT ALL JOINTS, PRIMER IS TO BE PURPLE IN COLOR
4) WHEN TIEING 2 OR MORE CONDENSATE LINES TOGETHER, INCREASE LINE SIZE TO 1"
5) CONDENSATE CANNOT TERMINATE AT A HARD SURFACE
6) T-STAT WIRE NOT INSTALLED
7) ALL CANS AND FITTINGS ARE TO BE INSULATED
8) PROVIDE FULL RADIUS BENDS ON FLEX DUCT
01/11/2011 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
02/15/2011 ELECTRIC - ABOVE CEILING RMORENO Approved
02/15/2011 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
02/24/2011 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
02/24/2011 PLUMBING - FINAL JMILITEL Approved IVRS - Inspection :*
02/24/2011 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
03/17/2011 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
001_T1.TIF CONSTRPLANS VIEW
002_C1.TIF CONSTRPLANS VIEW
003_A1.TIF CONSTRPLANS VIEW
004_M1 & P1.TIF CONSTRPLANS VIEW
005_E1.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
001_PLUMBING.TIF CONSTRPLANS VIEW
002_ELECTRICAL PLAN.TIF CONSTRPLANS VIEW