Permit: T10CM02384
Permit Details
Apply Date:
08/27/2010
Applicant:
N/A
Description:
REPAIRS:GENERAL T10DV05668
Contractors:
- B K STERLING L L C
Permit Reviews
Permit Number - T10CM02384
Permit Status: Final
Permit Description: REPAIRS:GENERAL T10DV05668
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/27/2010 | COMMERCIAL TI | 10/05/2010 | COMPLETED |
10/05/2010 | OTHER | 10/07/2010 | COMPLETED |
10/26/2010 | REVISION - - 1ST | 11/08/2010 | COMPLETED |
11/08/2010 | REVISION - - 1ST | 11/30/2010 | COMPLETED |
11/30/2010 | REVISION - - 2ND | 12/01/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM02384
Permit Status: Final
Permit Description: REPAIRS:GENERAL T10DV05668
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/27/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10CM02384
Permit Description: REPAIRS:GENERAL T10DV05668
Total Completed Inspections - 13
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/08/2010 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
12/27/2010 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) LEAK BEHIND TUB 2) T & P DRAIN NOT SIZED PROPERLY SECURE DIVERTERS 3) SEPERATE STOPS REQUIRED 4) INSTALL ISOLATION SUPPORTS AT TOP PLATE PENETRATIONS 5) INSTALL HB VAC BREAKER 6) INSTALL TRAP PRIMER AT FD |
12/27/2010 | ELECTRIC - INTERMEDIATE | RMORENO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 801 N. SWAN RD: 1) RISER TO SERVICE TO BE RE-STRAPPED, ANCHORED TO WALL 2) FEEDER TO SUB PANEL MISSING CONNECTOR 3) 1/2 OUTLET EMT MISSING STRAPPING BOX TO BE ANCHORED 803 N. SWAN RD: 1) FEEDER TO SUB PANEL MISSING CONNECTOR 2) 1/2 OUTLET EMT MISSING STRAPPING AND BOX TO BE ANCHORED 805 N. SWAN RD: 1) FEEDER TO SUB PANEL MISSING CONNECTOR 2) 1/2 OUTLET EMT MISSING STRAPPING AND BOX TO BE ANCHORED 3) REMOVE WIRE AND BOXES NOT BEING USED |
12/27/2010 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
12/27/2010 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
12/30/2010 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 2" DUCT LINER OR ROOF TOP DUCT (R-8), PROVIDE R-8 ON ALL DUCT IN ATTIC SPACE 2) CEILING DIFFUSERS ARE TO BE FRAMED ON 3 SIDES 3) ALL PVC PIPE IS TO BE PRIMERED AT ALL JOINTS, PRIMER IS TO BE PURPLE IN COLOR 4) WHEN TIEING 2 OR MORE CONDENSATE LINES TOGETHER, INCREASE LINE SIZE TO 1" 5) CONDENSATE CANNOT TERMINATE AT A HARD SURFACE 6) T-STAT WIRE NOT INSTALLED 7) ALL CANS AND FITTINGS ARE TO BE INSULATED 8) PROVIDE FULL RADIUS BENDS ON FLEX DUCT |
01/11/2011 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
02/15/2011 | ELECTRIC - ABOVE CEILING | RMORENO | Approved | |
02/15/2011 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* |
02/24/2011 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
02/24/2011 | PLUMBING - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
02/24/2011 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
03/17/2011 | PERMIT FINALED | JWEATHER | Approved |