Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
8424 E OLD SPANISH TR
Apply Date:
08/11/2010
Applicant:
N/A
Description:
TI: RESTAURANT/BAR/OFFICE (VETERANS OF FOREIGN WARS)
Architects:
  • ANDERSON STUDIO ARCHITECTS
Contractors:
  • GALILEO CONSTRUCTION L L C

Permit Reviews

Permit Number - T10CM02211
Permit Status: C of o
Permit Description: TI: RESTAURANT/BAR/OFFICE (VETERANS OF FOREIGN WARS)
Start Date Submittal Complete Date Status  
01/14/2011 3RD PARTY REVIEW - REVISION/OTHER 01/14/2011 COMPLETED Review Details
08/11/2010 PLANS OK TO SUBMIT - COMM 08/16/2010 COMPLETED Review Details
08/11/2010 PLANS OK TO SUBMIT - SITE 08/16/2010 COMPLETED Review Details
08/16/2010 PLANS OK TO SUBMIT - 3RD PARTY 08/16/2010 COMPLETED Review Details
08/16/2010 3RD PARTY REVIEW-COMMERCIAL TI 10/04/2010 COMPLETED Review Details
08/19/2010 SITE 09/15/2010 COMPLETED Review Details
09/17/2010 RESUBMITTAL - SITE ALL 10/04/2010 COMPLETED Review Details
10/04/2010 POST 3RD PARTY REVIEW 10/04/2010 COMPLETED Review Details
12/13/2010 3RD PARTY REVIEW - REVISION/OTHER 12/16/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM02211
Permit Status: C of o
Permit Description: TI: RESTAURANT/BAR/OFFICE (VETERANS OF FOREIGN WARS)
Total Outstanding Activity Conditions - 1
Date Name
08/11/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM02211
Permit Description: TI: RESTAURANT/BAR/OFFICE (VETERANS OF FOREIGN WARS)
Total Completed Inspections - 41
Date Description Inspector Results Comments
10/05/2010 ROOF NAILING JBURGE Approved IVRS - Inspection :*
1) OK TO DRY IN
10/05/2010 SITE - SEWER RRICH Approved IVRS - Inspection :*
1) FROM INTERCEPTOR TO EXISTING SEWER WATER TEST OK
2) NEED TEST ON INLET AND OUTLET OF INTERCEPTOR
10/06/2010 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
10/06/2010 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
10/19/2010 EXCAVATION/LAYOUT REBAR & ZON MHENSON Approved IVRS - Inspection :*
1) COLUMN FOOTING FOR SLIDING PARTITION
10/19/2010 BUILDING PRE-SLAB MHENSON Approved IVRS - Inspection :*
10/26/2010 STEM WALL/RETAINING WALL MHENSON Approved IVRS - Inspection :*
10/27/2010 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
10/27/2010 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
10/29/2010 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
10/29/2010 EXT METAL CLIPS/EXT SHEATHING MHENSON Approved IVRS - Inspection :*
11/02/2010 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
11/03/2010 STUCCO MESH MHENSON Approved IVRS - Inspection :*
1) ALL BUT NEW ADDITION
11/18/2010 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*CLOSET FLANGES OK ON PARTIAL
NEED CITY OF TUCSON APPROVAED REVISION
11/18/2010 BUILDING ABOVE CEILING MHENSON Approved IVRS - Inspection :*KITCHEN AREA GRID OK NO TILES WITH OUT TRADE INSPECTORS OK
11/18/2010 REINFORCED MASONRY PRE-GROUT MHENSON Approved IVRS - Inspection :*
11/18/2010 ELECTRIC - PROGRESS RHOLLAND Approved IVRS - Inspection :*
12/16/2010 BUILDING - PROGRESS GDABBS Approved IVRS - Inspection :*
12/16/2010 FRAMING GDABBS Approved IVRS - Inspection :*
12/16/2010 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
12/17/2010 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
12/17/2010 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
12/20/2010 MECHANICAL - HOOD SYSTEMS JMILITEL Approved IVRS - Inspection :*
12/20/2010 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
12/22/2010 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
12/29/2010 ENGINEERING - FINAL DLROBERTS Approved THE FOLLOWING ITEMS WERE NOTED AS NOT BEING PER THE APPROVED PLANS AND EITHER NEED TO BE APPROVEDF ON A REVISED SET OF DRAWINGS OR CHANGED IN THE FIELD TO MEET OUR SPECIFICATIONS.
1) AREAS OF THE SIDEWALK ON THE EAST SIDE OF THE BUILDING IS LESS THAN 48" IN WIDTH, THIS WILL REQUIRE A DSMR.
2) TRUNCATED DOMES ON THE NORTHSIDE OF THE SOUTHEN PARKING LOT ARE MISSING IN THE ACCESS AISLE ACROSS THE P.A.A.L. FROM THE PARKING LOT TO THE BUILDING. THESE NEED TO BE INSTALLED PRIOR TO CALLING IN THE FINAL INSPECTION.
3) MISSING PARKING BLOCKS ON THE SOUTHSIDE OF THE SOUTHERN PARKING LOT. ALSO ONE OF THE SPACES HAVE BEEN DELETED FROM THE PARKING AREA AND PLACED IN THE PARKING LOT EAST OF THE BUILDING. THESE CHANGES SHOULD BE REFLECTED IN THE REVISED DRAWNGS PRIOR TO CALLING IN THE FINAL INSPECTION FOR THIS SITE.
4)THE TRASH ENCLOSURE IS NOT PER THE APPROVED PLANS FOR THE INTERIOR SIZE. THIS CAN BE ACCEPTED IN ITS CURRENT STATE (9' W X 9.5' D) WITH AN ACCEPTANCE LETTER FROM ENVIRONMETAL SERVICES.
5) THE SIDEWALK CROSS SLOPE ON THE SOUTH SIDE OF THE BUILDING IS OUT OF SPEC IN THE AREA OF THE BUILDING. CURRENTLY THIS AREA IS AT 2.5% CROSS SLOPE AND SHOULD NOT EXCEED 2%.
6) THE EAST SIDE HANDICAP PARKING SIGNS ARE NOT AT AN ACCEPTABLE HEIGHT. CURRENTLY THE SIGNS ARE SET FOR 5' 6" AND NEED BE TO RAISED TO 7' TO THE BOTTOM OF THE SIGN.
12/29/2010 NPPO - FINAL DLROBERTS Approved
12/29/2010 LANDSCAPE - FINAL DLROBERTS Approved
12/29/2010 FIRE SPKLR - FINAL DSIWARSKI Approved
12/29/2010 FIRE - FINAL DSIWARSKI Approved
12/29/2010 RIGHT OF WAY - FINAL P.Whiddon Approved
01/05/2011 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
01/05/2011 ELECTRIC - OUTDOOR LIGHTING RJIROUDE Approved IVRS - Inspection :*
01/05/2011 ELECTRIC - RECONNECT RJIROUDE Approved IVRS - Inspection :*
01/05/2011 ELECTRIC - UFER RJIROUDE Approved IVRS - Inspection :*
01/06/2011 FIRE - KITCHEN EXH HOOD FINAL DRamirez Approved Approved 01/06/11
01/07/2011 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
1) TESTED CAPTURE AND CONTAINMENT, HEAT SENSOR AND DUCT SMOKE DETECTORS
2) OK FOR FINAL
01/13/2011 SIGN - FINAL ACONNOR Approved
01/19/2011 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
02/15/2011 HEALTH DEPT - FINAL 724-7908 NRAMIREZ Approved
03/09/2011 BUILDING - FINAL LHANLY Approved

Documents

File Name Document Type  
T10CM02211.PDF CERT OF OCC VIEW
TEMP C OF O_01-21-2011.TIF CERT OF OCC VIEW
C OF O_03-16-2011.TIF CERT OF OCC VIEW
000_3236.JPG SIGNS VIEW
001_CS.TIF CONSTRPLANS VIEW
002_ASP.TIF CONSTRPLANS VIEW
003_ALP.TIF CONSTRPLANS VIEW
004_AD2.TIF CONSTRPLANS VIEW
005_CS.TIF CONSTRPLANS VIEW
006_ASP.TIF CONSTRPLANS VIEW
007_ALP.TIF CONSTRPLANS VIEW
008_S-0.0.TIF CONSTRPLANS VIEW
009_S-1.0.TIF CONSTRPLANS VIEW
010_S-2.0.TIF CONSTRPLANS VIEW
011_S-3.0.TIF CONSTRPLANS VIEW
012_SD-1.TIF CONSTRPLANS VIEW
013_SD-2.TIF CONSTRPLANS VIEW
014_SD-3.TIF CONSTRPLANS VIEW
015_SD-4.TIF CONSTRPLANS VIEW
016_A1.TIF CONSTRPLANS VIEW
017_A2.TIF CONSTRPLANS VIEW
018_A3.TIF CONSTRPLANS VIEW
019_A4.TIF CONSTRPLANS VIEW
020_A5.TIF CONSTRPLANS VIEW
021_A6.TIF CONSTRPLANS VIEW
022_A7.TIF CONSTRPLANS VIEW
023_A8.TIF CONSTRPLANS VIEW
024_AD1.TIF CONSTRPLANS VIEW
025_AD2.TIF CONSTRPLANS VIEW
026_M1.0.TIF CONSTRPLANS VIEW
027_M1.1.TIF CONSTRPLANS VIEW
028_M1.2.TIF CONSTRPLANS VIEW
029_M2.0.TIF CONSTRPLANS VIEW
030_M3.0.TIF CONSTRPLANS VIEW
031_M3.1.TIF CONSTRPLANS VIEW
032_M4.0.TIF CONSTRPLANS VIEW
033_PD1.0.TIF CONSTRPLANS VIEW
034_P1.0.TIF CONSTRPLANS VIEW
035_P1.1.TIF CONSTRPLANS VIEW
036_P1.2.TIF CONSTRPLANS VIEW
037_P2.0.TIF CONSTRPLANS VIEW
038_P2.1.TIF CONSTRPLANS VIEW
039_P2.2.TIF CONSTRPLANS VIEW
040_P2.3.TIF CONSTRPLANS VIEW
041_E1.TIF CONSTRPLANS VIEW
042_E2.TIF CONSTRPLANS VIEW
043_E3.TIF CONSTRPLANS VIEW
044_E4.TIF CONSTRPLANS VIEW
045_E5.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW
None DOCUMENTS VIEW
2011_01_20 MARIO SANCHEZ.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW