Permit: T10CM02211
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
8424 E OLD SPANISH TR
Address NEW:
8424 E OLD SPANISH TR
Apply Date:
08/11/2010
Applicant:
N/A
Description:
TI: RESTAURANT/BAR/OFFICE (VETERANS OF FOREIGN WARS)
Architects:
- ANDERSON STUDIO ARCHITECTS
Contractors:
- GALILEO CONSTRUCTION L L C
Permit Reviews
Permit Number - T10CM02211
Permit Status: C of o
Permit Description: TI: RESTAURANT/BAR/OFFICE (VETERANS OF FOREIGN WARS)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/14/2011 | 3RD PARTY REVIEW - REVISION/OTHER | 01/14/2011 | COMPLETED |
| 08/11/2010 | PLANS OK TO SUBMIT - COMM | 08/16/2010 | COMPLETED |
| 08/11/2010 | PLANS OK TO SUBMIT - SITE | 08/16/2010 | COMPLETED |
| 08/16/2010 | PLANS OK TO SUBMIT - 3RD PARTY | 08/16/2010 | COMPLETED |
| 08/16/2010 | 3RD PARTY REVIEW-COMMERCIAL TI | 10/04/2010 | COMPLETED |
| 08/19/2010 | SITE | 09/15/2010 | COMPLETED |
| 09/17/2010 | RESUBMITTAL - SITE ALL | 10/04/2010 | COMPLETED |
| 10/04/2010 | POST 3RD PARTY REVIEW | 10/04/2010 | COMPLETED |
| 12/13/2010 | 3RD PARTY REVIEW - REVISION/OTHER | 12/16/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM02211
Permit Status: C of o
Permit Description: TI: RESTAURANT/BAR/OFFICE (VETERANS OF FOREIGN WARS)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/11/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T10CM02211
Permit Description: TI: RESTAURANT/BAR/OFFICE (VETERANS OF FOREIGN WARS)
Total Completed Inspections - 41
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/05/2010 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO DRY IN |
| 10/05/2010 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* 1) FROM INTERCEPTOR TO EXISTING SEWER WATER TEST OK 2) NEED TEST ON INLET AND OUTLET OF INTERCEPTOR |
| 10/06/2010 | PLUMBING - PRE SLAB | RRICH | Approved | IVRS - Inspection :* |
| 10/06/2010 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
| 10/19/2010 | EXCAVATION/LAYOUT REBAR & ZON | MHENSON | Approved | IVRS - Inspection :* 1) COLUMN FOOTING FOR SLIDING PARTITION |
| 10/19/2010 | BUILDING PRE-SLAB | MHENSON | Approved | IVRS - Inspection :* |
| 10/26/2010 | STEM WALL/RETAINING WALL | MHENSON | Approved | IVRS - Inspection :* |
| 10/27/2010 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
| 10/27/2010 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 10/29/2010 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
| 10/29/2010 | EXT METAL CLIPS/EXT SHEATHING | MHENSON | Approved | IVRS - Inspection :* |
| 11/02/2010 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
| 11/03/2010 | STUCCO MESH | MHENSON | Approved | IVRS - Inspection :* 1) ALL BUT NEW ADDITION |
| 11/18/2010 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :*CLOSET FLANGES OK ON PARTIAL NEED CITY OF TUCSON APPROVAED REVISION |
| 11/18/2010 | BUILDING ABOVE CEILING | MHENSON | Approved | IVRS - Inspection :*KITCHEN AREA GRID OK NO TILES WITH OUT TRADE INSPECTORS OK |
| 11/18/2010 | REINFORCED MASONRY PRE-GROUT | MHENSON | Approved | IVRS - Inspection :* |
| 11/18/2010 | ELECTRIC - PROGRESS | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/16/2010 | BUILDING - PROGRESS | GDABBS | Approved | IVRS - Inspection :* |
| 12/16/2010 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 12/16/2010 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
| 12/17/2010 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
| 12/17/2010 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
| 12/20/2010 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | IVRS - Inspection :* |
| 12/20/2010 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 12/22/2010 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 12/29/2010 | ENGINEERING - FINAL | DLROBERTS | Approved | THE FOLLOWING ITEMS WERE NOTED AS NOT BEING PER THE APPROVED PLANS AND EITHER NEED TO BE APPROVEDF ON A REVISED SET OF DRAWINGS OR CHANGED IN THE FIELD TO MEET OUR SPECIFICATIONS. 1) AREAS OF THE SIDEWALK ON THE EAST SIDE OF THE BUILDING IS LESS THAN 48" IN WIDTH, THIS WILL REQUIRE A DSMR. 2) TRUNCATED DOMES ON THE NORTHSIDE OF THE SOUTHEN PARKING LOT ARE MISSING IN THE ACCESS AISLE ACROSS THE P.A.A.L. FROM THE PARKING LOT TO THE BUILDING. THESE NEED TO BE INSTALLED PRIOR TO CALLING IN THE FINAL INSPECTION. 3) MISSING PARKING BLOCKS ON THE SOUTHSIDE OF THE SOUTHERN PARKING LOT. ALSO ONE OF THE SPACES HAVE BEEN DELETED FROM THE PARKING AREA AND PLACED IN THE PARKING LOT EAST OF THE BUILDING. THESE CHANGES SHOULD BE REFLECTED IN THE REVISED DRAWNGS PRIOR TO CALLING IN THE FINAL INSPECTION FOR THIS SITE. 4)THE TRASH ENCLOSURE IS NOT PER THE APPROVED PLANS FOR THE INTERIOR SIZE. THIS CAN BE ACCEPTED IN ITS CURRENT STATE (9' W X 9.5' D) WITH AN ACCEPTANCE LETTER FROM ENVIRONMETAL SERVICES. 5) THE SIDEWALK CROSS SLOPE ON THE SOUTH SIDE OF THE BUILDING IS OUT OF SPEC IN THE AREA OF THE BUILDING. CURRENTLY THIS AREA IS AT 2.5% CROSS SLOPE AND SHOULD NOT EXCEED 2%. 6) THE EAST SIDE HANDICAP PARKING SIGNS ARE NOT AT AN ACCEPTABLE HEIGHT. CURRENTLY THE SIGNS ARE SET FOR 5' 6" AND NEED BE TO RAISED TO 7' TO THE BOTTOM OF THE SIGN. |
| 12/29/2010 | NPPO - FINAL | DLROBERTS | Approved | |
| 12/29/2010 | LANDSCAPE - FINAL | DLROBERTS | Approved | |
| 12/29/2010 | FIRE SPKLR - FINAL | DSIWARSKI | Approved | |
| 12/29/2010 | FIRE - FINAL | DSIWARSKI | Approved | |
| 12/29/2010 | RIGHT OF WAY - FINAL | P.Whiddon | Approved | |
| 01/05/2011 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
| 01/05/2011 | ELECTRIC - OUTDOOR LIGHTING | RJIROUDE | Approved | IVRS - Inspection :* |
| 01/05/2011 | ELECTRIC - RECONNECT | RJIROUDE | Approved | IVRS - Inspection :* |
| 01/05/2011 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* |
| 01/06/2011 | FIRE - KITCHEN EXH HOOD FINAL | DRamirez | Approved | Approved 01/06/11 |
| 01/07/2011 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) TESTED CAPTURE AND CONTAINMENT, HEAT SENSOR AND DUCT SMOKE DETECTORS 2) OK FOR FINAL |
| 01/13/2011 | SIGN - FINAL | ACONNOR | Approved | |
| 01/19/2011 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 02/15/2011 | HEALTH DEPT - FINAL 724-7908 | NRAMIREZ | Approved | |
| 03/09/2011 | BUILDING - FINAL | LHANLY | Approved |