Permit: T10CM02211

Parcel: 13409002E

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/19/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
01/18/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SEE NOTE #2 FROM 1/6/11 INSPECTION HISTORY AND PROVIDE CORRECT BACKFLOW FOR DEVICES
01/07/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CALL IN ALL PLUMBING INSPECTIONS THAT HAVE NOT BEEN APPROVED
2) PROVIDE BACKFLOW PROTECTION FOR CARBONATOR AND WATER SUPPORT TO NON CARBONATED BEVERAGES
3) PROVIDE CORRECT DRAIN AND TRAP FOR BAR AREA 3 COMP SINK
4) PROVIDE CORRECT VENT THRU CEILING FOR WATER HEATER
5) COMPLETE INSULATION AT WATER HEATER
6) INSTALL GRATES AND STRAINER DOMES AT FLOOR SINKS
7) PROVIDE IDENTIFICATION FOR ANSUL VALVE
8) INSTALL ACCESS PANELS AND VENTED LOUVERS FOR AIR ADDMITTANCE VALVES
9) PROVIDE CITY APPROVED REVISED PLANS AS REQUIRED AT PREVIOUS INSPECTION