Permit: T10CM02211

Parcel: 13409002E

Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Date Description Inspector Results Comments
03/09/2011 ENGINEERING - FINAL Approved THIS SITE IS BEING APPROVED AS REQUESTED BY RON BOOSE THE BUILDING OFFICIAL UTILIZING THE FOLLOWING ITEMS AS THE BASIS OF THE ACCEPTANCE: BUILDING OFFICIALS E-MAIL FOR THE VARIANCE OF THE ADA STANDARD, AND THE ACCEPTANCE LETTER FROM CITY OF TUCSON ENVIRONMENTAL SERVICES.

Dave,

Per our conversation earlier today, the variance in cross slope of the accessible sidewalk and length of that variation is rather minor in the scope of the project and can be accepted as within normal construction tolerances. I believe this is the last remaining item to final this project and issue a permanent CO. Please result your remaining inspection accordingly.

Thank you,

Ron

Mario A. Sanchez, A.I.T.
1643 N. Alvernon Way, Suite 106
Tucson, AZ 85712
January 20, 2011
Subject: V.F.W. Post 549, Tenant Improvement
8424 E. Old Spanish Trail, Tucson, AZ 857
Activity No.T10CM02211
After reviewing the Solid Waste container enclosure for the Tenant Improvement at the V.F.W.
Post 549, Activity No.T10CM02211, the constructed enclosure was found to be built not in
accordance with Environmental Services Solid Waste Disposal and Recycle Materials Standers
No. 6-01.0. The Environmental Services Department, will allow the Solid Waste enclosure as
constructed. However, because the enclosure width was constructed with a 9’-6” opening and not
a minimum of a 10 ft clear opening. A note must be added to the improvement plans stating that
the owner will be responsible for any damages to the Solid Waste enclosure which may result
from the day-to-day operation of solid waste collection services, for this facility.
City of Tucson
Environmental Services Department
Development Plan Review
Reviewer: Tony Teran, P.E.
Office Phone (520) 837-3706
E-mail: Tony.Teran @tucsonaz.gov
01/19/2011 ENGINEERING - FINAL Partial Approval ITEMS NUMBERED 1,4, AND 5 FROM THE PREVIOUS PUNCHLIST DATED 12/29/2010 STILL NEED TO BE COMPLETED. ITEMS 2, 3, AND 6 HAVE BEEN CORRECTED AND APPROVED AT THIS TIME.
12/29/2010 ENGINEERING - FINAL Partial Approval THE FOLLOWING ITEMS WERE NOTED AS NOT BEING PER THE APPROVED PLANS AND EITHER NEED TO BE APPROVEDF ON A REVISED SET OF DRAWINGS OR CHANGED IN THE FIELD TO MEET OUR SPECIFICATIONS.
1) AREAS OF THE SIDEWALK ON THE EAST SIDE OF THE BUILDING IS LESS THAN 48" IN WIDTH, THIS WILL REQUIRE A DSMR.
2) TRUNCATED DOMES ON THE NORTHSIDE OF THE SOUTHEN PARKING LOT ARE MISSING IN THE ACCESS AISLE ACROSS THE P.A.A.L. FROM THE PARKING LOT TO THE BUILDING. THESE NEED TO BE INSTALLED PRIOR TO CALLING IN THE FINAL INSPECTION.
3) MISSING PARKING BLOCKS ON THE SOUTHSIDE OF THE SOUTHERN PARKING LOT. ALSO ONE OF THE SPACES HAVE BEEN DELETED FROM THE PARKING AREA AND PLACED IN THE PARKING LOT EAST OF THE BUILDING. THESE CHANGES SHOULD BE REFLECTED IN THE REVISED DRAWNGS PRIOR TO CALLING IN THE FINAL INSPECTION FOR THIS SITE.
4)THE TRASH ENCLOSURE IS NOT PER THE APPROVED PLANS FOR THE INTERIOR SIZE. THIS CAN BE ACCEPTED IN ITS CURRENT STATE (9' W X 9.5' D) WITH AN ACCEPTANCE LETTER FROM ENVIRONMETAL SERVICES.
5) THE SIDEWALK CROSS SLOPE ON THE SOUTH SIDE OF THE BUILDING IS OUT OF SPEC IN THE AREA OF THE BUILDING. CURRENTLY THIS AREA IS AT 2.5% CROSS SLOPE AND SHOULD NOT EXCEED 2%.
6) THE EAST SIDE HANDICAP PARKING SIGNS ARE NOT AT AN ACCEPTABLE HEIGHT. CURRENTLY THE SIGNS ARE SET FOR 5' 6" AND NEED BE TO RAISED TO 7' TO THE BOTTOM OF THE SIGN.