Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Apply Date:
06/14/2010
Applicant:
N/A
Description:
ADDITION:2 BEDROOMS:RELOCATE:BATHROOM / ADULTCARE HOME 5 CLIENTS

Permit Reviews

Permit Number - T10CM01592
Permit Status: Final
Permit Description: ADDITION:2 BEDROOMS:RELOCATE:BATHROOM / ADULTCARE HOME 5 CLIENTS
Start Date Submittal Complete Date Status  
06/14/2010 RESIDENTIAL BLDG/ZONING-WALKTHRU 06/15/2010 COMPLETED Review Details
06/17/2010 RESIDENTIAL BLDG/WWM 07/16/2010 COMPLETED Review Details
07/21/2010 RESUBMITTAL 07/30/2010 COMPLETED Review Details
10/08/2010 REVISION - - 1ST 10/08/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM01592
Permit Status: Final
Permit Description: ADDITION:2 BEDROOMS:RELOCATE:BATHROOM / ADULTCARE HOME 5 CLIENTS
Total Outstanding Activity Conditions - 1
Date Name
06/14/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T10CM01592
Permit Description: ADDITION:2 BEDROOMS:RELOCATE:BATHROOM / ADULTCARE HOME 5 CLIENTS
Total Completed Inspections - 23
Date Description Inspector Results Comments
08/09/2010 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
08/16/2010 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
08/16/2010 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
09/09/2010 ROOF NAILING JBURGE Approved IVRS - Inspection :*
1) OK TO DRY IN
09/09/2010 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
1) OK TO STUCCO MESH
10/07/2010 STUCCO MESH DWALKER Approved
11/03/2010 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
1) DUCT IN SOFFIT OK TO COVER
11/03/2010 FRAMING JBURGE Approved IVRS - Inspection :*
1) CALL BACK FOR DOOR WAY TO EXISTING HOUSE
11/03/2010 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
11/03/2010 ELECTRIC - SERVICE RELOCATION DWALKER Approved IVRS - Inspection :*
11/04/2010 TEP CLEARANCE - AM JWEATHER Approved ECO/RELOCATION PER D. WALKER
11/05/2010 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) OPEN CONDUCTORS ARE NOT APPROVED WIRING METHODS
2) SUB PANEL NOT SHOWN ON PLANS
3) BATHROOM RECEPT CIRCUIT TO SERVE NO OTHER OUTLETS
4) CEILING FANS NOT ON PLANS
5) ROMEX SHEATH TO EXTEND 1/4" MIN INTO BOX
6) ROMEX TO BE STAPLED WITHING 8" OF BOXES
7) ROMEX CANNOT BE EMBEDDED INTO CONCRETE
8) PANEL CANNOT BE INSTALLED IN CLOTHES CLOSET
9) CLOSET LIGHTS TO MEET MINIMUM CLEARANCE REQUIREMENTS NEC 410
11/05/2010 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved IVRS - Inspection :*
1) SHADE PLASTIC GAS PIPE WITH CLEAN FILL PRIOR TO COVERING
11/05/2010 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) POINT OF VENT MAY NOT BE BELOW WEIR OF TRAP
2) PLAN INDICATES 1" CW
11/05/2010 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved IVRS - Inspection :*
06/14/2011 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
08/29/2011 PLUMBING - GAS PRESSURE TEST JBURGE Approved IVRS - Inspection :*
09/09/2011 PLUMBING - FINAL JBURGE Approved IVRS - Inspection :*
09/22/2011 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
09/26/2011 CERTIFICATE OF OCCUPANCY JBURGE Approved IVRS - Inspection :*
09/26/2011 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
09/26/2011 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
09/29/2011 FIRE - FINAL MPURSLEY Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
001_FLOOR & SITE PLAN.TIF CONSTRPLANS VIEW
002_ELEVATION.TIF CONSTRPLANS VIEW
003_PLUMBING.TIF CONSTRPLANS VIEW
004_ELEC & MECH.TIF CONSTRPLANS VIEW
005_DETAILS.TIF CONSTRPLANS VIEW