Permit: T10CM01592
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
6313 E CALLE DE SAN ALBERTO
Address NEW:
6313 E CALLE DE SAN ALBERTO
Apply Date:
06/14/2010
Applicant:
N/A
Description:
ADDITION:2 BEDROOMS:RELOCATE:BATHROOM / ADULTCARE HOME 5 CLIENTS
Permit Reviews
Permit Number - T10CM01592
Permit Status: Final
Permit Description: ADDITION:2 BEDROOMS:RELOCATE:BATHROOM / ADULTCARE HOME 5 CLIENTS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/14/2010 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 06/15/2010 | COMPLETED |
| 06/17/2010 | RESIDENTIAL BLDG/WWM | 07/16/2010 | COMPLETED |
| 07/21/2010 | RESUBMITTAL | 07/30/2010 | COMPLETED |
| 10/08/2010 | REVISION - - 1ST | 10/08/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM01592
Permit Status: Final
Permit Description: ADDITION:2 BEDROOMS:RELOCATE:BATHROOM / ADULTCARE HOME 5 CLIENTS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/14/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10CM01592
Permit Description: ADDITION:2 BEDROOMS:RELOCATE:BATHROOM / ADULTCARE HOME 5 CLIENTS
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2010 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
| 08/16/2010 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* |
| 08/16/2010 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* |
| 09/09/2010 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO DRY IN |
| 09/09/2010 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO STUCCO MESH |
| 10/07/2010 | STUCCO MESH | DWALKER | Approved | |
| 11/03/2010 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* 1) DUCT IN SOFFIT OK TO COVER |
| 11/03/2010 | FRAMING | JBURGE | Approved | IVRS - Inspection :* 1) CALL BACK FOR DOOR WAY TO EXISTING HOUSE |
| 11/03/2010 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
| 11/03/2010 | ELECTRIC - SERVICE RELOCATION | DWALKER | Approved | IVRS - Inspection :* |
| 11/04/2010 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO/RELOCATION PER D. WALKER |
| 11/05/2010 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) OPEN CONDUCTORS ARE NOT APPROVED WIRING METHODS 2) SUB PANEL NOT SHOWN ON PLANS 3) BATHROOM RECEPT CIRCUIT TO SERVE NO OTHER OUTLETS 4) CEILING FANS NOT ON PLANS 5) ROMEX SHEATH TO EXTEND 1/4" MIN INTO BOX 6) ROMEX TO BE STAPLED WITHING 8" OF BOXES 7) ROMEX CANNOT BE EMBEDDED INTO CONCRETE 8) PANEL CANNOT BE INSTALLED IN CLOTHES CLOSET 9) CLOSET LIGHTS TO MEET MINIMUM CLEARANCE REQUIREMENTS NEC 410 |
| 11/05/2010 | PLUMBING - GAS PRESS TEST FNL | BBENEDON | Approved | IVRS - Inspection :* 1) SHADE PLASTIC GAS PIPE WITH CLEAN FILL PRIOR TO COVERING |
| 11/05/2010 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) POINT OF VENT MAY NOT BE BELOW WEIR OF TRAP 2) PLAN INDICATES 1" CW |
| 11/05/2010 | PLUMBING - GAS PRESS TEST FNL | BBENEDON | Approved | IVRS - Inspection :* |
| 06/14/2011 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
| 08/29/2011 | PLUMBING - GAS PRESSURE TEST | JBURGE | Approved | IVRS - Inspection :* |
| 09/09/2011 | PLUMBING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 09/22/2011 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 09/26/2011 | CERTIFICATE OF OCCUPANCY | JBURGE | Approved | IVRS - Inspection :* |
| 09/26/2011 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 09/26/2011 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* |
| 09/29/2011 | FIRE - FINAL | MPURSLEY | Approved |