Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2011 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/16/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) SHOWER DRAIN TO LINER CONNECTION OK FOR TILE |
|
| 08/15/2011 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER PROOFING IS APPLIED TO THE COVER HALF OF DRAIN BODY-THEN THE UPER SECTION IS BOLTED DOWN |
|
| 08/10/2011 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 PIECE FHA DRAIN REQUIRED, WATER PROOFING SEALS TO LOWER DRAIN BODY AND WEEP HOLES REMAIN OPEN |
|
| 06/06/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* YARD PIPING OK. TESTS OK. WALLS OK TO COVER PROVIDE FULL SIZE TOE AT WH/FUR. CORRECT VENT RECALL FOR INSPECTION OF SHOWER PAN LINER PRIOR TO TILE. SUPPORT CLOSET FLANGE AND SECURE |
|
| 06/01/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) COURTESY INSPECTION FOR NEVIN (OWNER) 2) SQUARE SHOWER DIVERTER WITH WALL AND TEST ALL JOINTS 3) SECURE YARD WATER PIPING IN WALLS 4) YARD WATER OK, PROTECT CU PENETRATING STUCCO 5) INSTALL HOSE BIB VACUUM BREAKER OR REMOVE HB |
|
| 05/16/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PLAN INDICATES 1" SUPPLY TO FIRST BRANCH 2) 1/2" SUPPLY TO (2) WASHER BOXES IS UNDERSIZED, BRING 3/4" OVER TO FIRST BRANCH 3) SECURE ALL TUBING AND PIPING AS REQUIRED 4) SECURE SHOWER VALVE SO THAT IS SQUARE WITH WALL 5) TRANSITION GLUE IS NOT APPROVED FOR USE INSIDE BLDG 6) FLANGE SHALL REST ON FINISHED FLOOR 7) CALL FOR INSPECTION SHOWER PAN LINER WHEN READY |
|
| 11/05/2010 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POINT OF VENT MAY NOT BE BELOW WEIR OF TRAP 2) PLAN INDICATES 1" CW |
|
| 11/03/2010 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CLEANOUTS REQUIRED ON WASHERS AND SINKS 2) A SAN TEE MAY NOT BE USED HORIZONTALLY BELOW THE FLOOD LEVEL OF THE FIXTURE 3) A VENT MUST RISE VERTICAL TO A POINT 6" ABOVE FLOOD LEVEL 4) VENTS MAY NOT COMBINE BELOW FLOOD LEVEL 5) PROVIDE APPROVED DRAINAGE FITTINGS 6) REMOVE ANY FLUX RESIDUE FROM COPPER, ALL JOINTS IN COPPER SHALL BE REAMED 7) SECURE DIVERTER VALVE 8) PERM CAP DEMO |