Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
3400 E ZOO CT
Address NEW:
3400 E ZOO CT
Apply Date:
04/07/2010
Applicant:
N/A
Description:
BLDG#3:LSS
Contractors:
  • ASHTON COMPANY INC CONTRACTORS *T

Permit Reviews

Permit Number - T10CM00917
Permit Status: C of o
Permit Description: BLDG#3:LSS
Start Date Submittal Complete Date Status  
04/30/2010 COMMERCIAL TI 07/09/2010 COMPLETED Review Details
07/09/2010 RESUBMITTAL - TI ALL 09/10/2010 COMPLETED Review Details
08/02/2011 REVISION - - 1ST 09/15/2011 COMPLETED Review Details
09/10/2010 RESUBMITTAL 12/17/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM00917
Permit Status: C of o
Permit Description: BLDG#3:LSS
Total Outstanding Activity Conditions - 1
Date Name
04/07/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM00917
Permit Description: BLDG#3:LSS
Total Completed Inspections - 31
Date Description Inspector Results Comments
06/21/2011 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
07/15/2011 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
1) 4" SDR 35 FROM NEW MANHOLE AT NORTHWEST CORNER OF LSS TO 4" SADDLE TAP ON EXISTING CLAY
2) WATER TEST
3) PROVIDE CITY APPROVED PLAN OF THIS INSTALLATION-APPROVED PLAN PAGE OC-201 SHOWS EXISTING MANHOLE FOR TERMINATION POINT
07/26/2011 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
1) COATING INSTALLED NEW MANHOLE NOTE #9 OC-201 WITH HOLIDAYS TEST
2) LSS EXTERIOR PIPING INSPECTED ON PERMIT #T10CM00802 ALL EXTERIOR OK
08/09/2011 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
1) YARDWATER TO #3 OSS OK
2) NEED TO SEE BLDG CONNECTION
3) PRESSURE TEST OK-OK TO COVER
08/11/2011 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection :*
08/24/2011 REINFORCED MASONRY PRE-GROUT MHENSON Approved IVRS - Inspection :*
09/09/2011 BUILDING PRE-SLAB MHENSON Approved IVRS - Inspection :*
09/09/2011 STEM WALL/RETAINING WALL MHENSON Approved IVRS - Inspection :*
09/09/2011 EXCAVATION/LAYOUT REBAR & ZON MHENSON Approved IVRS - Inspection :*
10/14/2011 ROOF NAILING MHENSON Approved IVRS - Inspection :*
1) OK TO INSTALL METAL ROOFING
10/14/2011 FRAMING MHENSON Approved IVRS - Inspection :*
10/27/2011 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
1) DRAIN WASTE AND VENT LSS OK EXCEPT FOR 2-4" P-TRAPS WITH VENTING FOR ABOVE SLAB
12/06/2011 ELECTRIC - PROGRESS DSANTACR Approved IVRS - Inspection :*
12/06/2011 ELECTRIC - TEMPORARY SERVICE DSANTACR Approved IVRS - Inspection :*
12/06/2011 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
12/06/2011 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
12/06/2011 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection :*
01/10/2012 BUILDING - PROGRESS JBURGE Approved IVRS - Inspection :*
01/10/2012 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
01/10/2012 STUCCO MESH JBURGE Approved IVRS - Inspection :*
01/10/2012 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
01/17/2012 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
01/23/2012 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
01/23/2012 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
01/31/2012 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
02/01/2012 FIRE - FINAL WMOTTO Approved
02/01/2012 NPPO - FINAL RLEDONNE Approved
02/01/2012 LANDSCAPE - FINAL RLEDONNE Approved
02/01/2012 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
02/02/2012 SIGN - FINAL RLEDONNE Approved NA TO THIS ACTIVITY.
02/13/2012 ENGINEERING - FINAL RLEDONNE Approved