Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T10CM00541
Permit Details
Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
6224 E SPEEDWAY BL
Address NEW:
6224 E SPEEDWAY BL
Apply Date:
03/05/2010
Applicant:
N/A
Description:
TI:RETAIL
Contractors:
- HAZEN LTD , STEVE
Permit Reviews
Permit Number - T10CM00541
Permit Status: Final
Permit Description: TI:RETAIL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/05/2010 | COMMERCIAL TI | 03/15/2010 | COMPLETED |
| 03/15/2010 | COMMERCIAL TI | 03/18/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM00541
Permit Status: Final
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/05/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10CM00541
Permit Description: TI:RETAIL
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2010 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
| 04/19/2010 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
| 04/29/2010 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 04/29/2010 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1) INTERLOCK EXHAUST FAN WITH A/C SUPPLY FAN AS PER PLANS, WILL CHECK ON FINAL 2) FOR FINAL PROVIDE A FRESH AIR INTAKE, TERMINATE CONDENSATE TO AN APPROVED LOCATION, SUPPORT GAS LINE ON ROOF AND REPAIR BROKEN ELECTRIC CONDUIT TO DISCONNECT |
| 04/29/2010 | FRAMING | JBURGE | Approved | IVRS - Inspection :* APPROVED - OK TO SHEETROCK PENDING ELECTRIC INTERMEDIATE |
| 04/29/2010 | ELECTRIC - INTERMEDIATE | RMORENO | Approved | IVRS - Inspection :* WALLS, CEILINGS ALL OK NEED TO SEE 10 VOLTAGE STRAPED OR REMOVE. |
| 04/29/2010 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
| 04/29/2010 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
| 05/05/2010 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
| 06/02/2010 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR FINAL |
| 06/02/2010 | ELECTRIC - ABOVE CEILING | RMORENO | Approved | |
| 06/02/2010 | FIRE - FINAL | CSCHULTZ | Approved | |
| 06/02/2010 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 06/02/2010 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* |
| 06/02/2010 | RIGHT OF WAY - FINAL | PWhiddon | Approved | |
| 06/03/2010 | NPPO - FINAL | MRUSSO | Approved | |
| 06/03/2010 | LANDSCAPE - FINAL | MRUSSO | Approved | |
| 06/03/2010 | ENGINEERING - FINAL | MRUSSO | Approved | |
| 06/03/2010 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :$ |
| 06/03/2010 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection :* |
| 06/04/2010 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* 1) ALL TRADES AND FIRE FINALS ARE COMPLETE |
| 06/04/2010 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
| 06/04/2010 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* |
| 06/08/2010 | PERMIT FINALED | JWEATHER | Approved |