Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T10CM00541

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/29/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
04/27/2010 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) YOU LOST YOUR TEST, YOUR VENT AND DRAIN PIPING ARE OUT OF THE WALL
2) TRAP ARM CHANGE OF DITRECTION
3) REQUIRES A SWEEP, ALSO IS YOUR TRAP 2" ?
4) VENT IN WALL REQUIRES A CLAMP
5) VENT OVERHEAD REQUIRES TWO SUPPORTS
6) WATER LINE IN WALL NEEDS A CLAMP NEAR TOP PLATE
7) WATER SUPPLY AT WATER CLOSET MISSING SAFETY PLATE
8) PLAN SPECS CONCEALED ARM SUPPORT AT LAV