Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T10BU01806
Permit Details
Apply Date:
12/08/2010
Applicant:
N/A
Description:
GRADING/SWPPP- QUIK TRIP
Contractors:
- BARKER MORRISSEY CONTRACTING INC **C
Permit Reviews
Permit Number - T10BU01806
Permit Status: Final
Permit Description: GRADING/SWPPP- QUIK TRIP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/21/2011 | RESUBMITTAL - GRADING | 09/21/2011 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10BU01806
Permit Status: Final
Permit Description: GRADING/SWPPP- QUIK TRIP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/08/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10BU01806
Permit Description: GRADING/SWPPP- QUIK TRIP
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2011 | ENGINEERING PRE-CONSTRUCTION | MRUSSO | Approved | MET W/ SUPERINTENDENT ( BILL W/BARKER MORISSEY 260-7912) 1) RE-ESTABLISH ROCK ENTRANCE 2) SWEEP TRACKING OFF STONE 3) PROVIDE A DESIGNATED CONCRETE WASH OUT 4) POST A COPY OF YOUR SIGNED NOI 5) PROVIDE CLARIFICATION ON EAST DRAINAGE CHANNEL ( RIP RAP/CONCRETE) 6) IDENTIFY GRADING LIMIT 7) MAINTAIN SEDIMENT CONTROLS AND DOCUMENT SELF INSPECTIONS. 8) PROVIDE CLARIFICATION ON STORM PIPE INSTALLATION FROM YOUR ENG OF RECORD - SPECIFIC DETAILS USED FOR INSTALL |
| 12/06/2011 | GRADING - INTERMEDIATE | MRUSSO | Approved | 1) VERIFY INSTALL OF 150 LF OF 36"X3 SRP ALONG SOUTH SIDE OF SITE. TRENCH WAS COMPACTED, PIPE WAS BEDDED AND GRADED. NEOPRENE GASKET USED W/BOLTED COLLAR FOR CONNECTED PIPE. 2) INSTALL SEDIMENT CONTROLS ON S. SIDE OF EAST LOT. 3) INSTALL CONSTRUCTION ENTRANCE AT EACH ENTRANCE/EXIT IN ORDER TO REDUCE TRACKING. 5) REMOVE SOIL FROM CURB LINE |
| 12/14/2011 | STORMWATER FOLLOW-UP INSP | MRUSSO | Approved | NO STORM WATER CONCERNS AT THIS TIME, RAINING TODAY |
| 04/18/2012 | GRADING - TIER REV | MRUSSO | Approved | |
| 04/18/2012 | STORMWATER FINAL INSPECTION | MRUSSO | Approved | |
| 04/20/2012 | GRADING - FINAL | MRUSSO | Approved | |
| 07/14/2012 | GRADING - CHECK FOR ACTIVITY | DROBERTS | Approved | |
| 07/14/2012 | RAINWATER - INTERMEDIATE | DROBERTS | Approved | |
| 07/14/2012 | RAINWATER - FINAL | DROBERTS | Approved | |
| 07/14/2012 | GRADING - REBAR | DROBERTS | Approved | |
| 07/14/2012 | STORMWATER INSTALL OF CONTROLS | DROBERTS | Approved | |
| 10/14/2013 | INVESTIGATIVE INSPECTION | DROBERTS | Approved | THIS SITE HAS BEEN INSPECTED TO VERIFY THAT IT HAS MET THE CONDITIONS. IT APPEARS THAT THE ZONING CONDITIONS HAVE ALL BEEN MET AND THAT THIS CASE CAN BE CLOSED AT THIS TIME. |