Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
Grading and SWPPP
Address:
6350 E GRANT RD
Address NEW:
6350 E GRANT RD
Apply Date:
07/27/2010
Applicant:
N/A
Description:
GRADING FOR NEW PARKING LOT FOR CAR DEALERSHIP
Contractors:
  • CANYON BUILDING AND DESIGN L L C **C

Permit Reviews

Permit Number - T10BU01194
Permit Status: Final
Permit Description: GRADING FOR NEW PARKING LOT FOR CAR DEALERSHIP
Start Date Submittal Complete Date Status  
07/27/2010 PLANS OK TO SUBMIT - GRADING 07/27/2010 COMPLETED Review Details
07/27/2010 GRADING 08/19/2010 COMPLETED Review Details
08/26/2010 RESUBMITTAL - GRADING ALL 09/30/2010 COMPLETED Review Details
08/29/2011 REVISION - GRADING 03/14/2014 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10BU01194
Permit Status: Final
Permit Description: GRADING FOR NEW PARKING LOT FOR CAR DEALERSHIP
Total Outstanding Activity Conditions - 1
Date Name
07/27/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T10BU01194
Permit Description: GRADING FOR NEW PARKING LOT FOR CAR DEALERSHIP
Total Completed Inspections - 12
Date Description Inspector Results Comments
11/10/2010 ENGINEERING PRE-CONSTRUCTION MRUSSO Approved 1) SILT SOCK HAS BEEN INSTALLED ALONG PERIMETER AS SHOWN ON SWPPP - ENSURE SILT SOCK OVERLAPS EACH SECTION WHEN INSTALLED.
2) INSTALL A STABILIZED CONSTRUCTION ENTRANCE ALONG WILMONT ROAD.
3) POST A COPY OF YOUR AZCON AUTHORIZATION NUMBER ON SITE.
4) ENSURE PERIODIC STORM WATER MAINT SELF INSPECTIONS ARE PERFORMED AND DOCUMENTED PER YOUR SWPPP
5) SWEEP UP ANY TRACKED SOIL OFF PUBLIC ROADWAYS AS NEEDED.
12/07/2010 STORMWATER INSTALL OF CONTROLS MRUSSO Approved
12/27/2010 STORMWATER FOLLOW-UP INSP MRUSSO Approved NO ACTIVITY ON SITE, NO DRAINAGE PROBLEMS AFTER RAIN EVENT. NO STORM WATER CONCERNS AT THIS TIME
12/27/2010 GRADING - INTERMEDIATE MRUSSO Approved NO ACTIVITY ON SITE, NO DRAINAGE PROBLEMS AFTER RAIN EVENT. NO STORM WATER CONCERNS AT THIS TIME
08/24/2011 STORMWATER FINAL INSPECTION MRUSSO Approved
08/24/2011 LANDSCAPE INSPECTION MRUSSO Approved
08/24/2011 RAINWATER - FINAL MRUSSO Approved
08/24/2011 RAINWATER - INTERMEDIATE MRUSSO Approved
08/24/2011 GRADING - CHECK FOR ACTIVITY MRUSSO Approved
08/24/2011 GRADING - TIER REV MRUSSO Approved
08/30/2011 GRADING - REBAR JFEMLING Approved Approved
08/30/2011 GRADING - FINAL JFEMLING Approved Approved

Documents

File Name Document Type  
001_SHEET 1 OF 4.TIF GRADING PLANS VIEW
002_SHEET 2 OF 4.TIF GRADING PLANS VIEW
003_SHEET 3 OF 4.TIF GRADING PLANS VIEW
004_SHEET 4 OF 4.TIF GRADING PLANS VIEW
None DOCUMENTS VIEW
CERTIFICATION LETTER 2011.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW
REFUND T10BU01194 DOCUMENTS VIEW
PERFORMANCE BOND.PDF DOCUMENTS VIEW
BOND RELEASE LETTER 2011_11_10.PDF DOCUMENTS VIEW