Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ADDITION
Address NEW:
2051 W JIM HOWARD PL
Apply Date:
12/10/2009
Applicant:
N/A
Description:
ADDITION:SHOP BUILDING
Contractors:
  • PROCESS DESIGN BUILD L L C

Permit Reviews

Permit Number - T09CM03255
Permit Status: C of o
Permit Description: ADDITION:SHOP BUILDING
Start Date Submittal Complete Date Status  
03/09/2010 RESUBMITTAL 03/29/2010 COMPLETED Review Details
03/09/2010 RESUBMITTAL - SITE 03/29/2010 COMPLETED Review Details
05/07/2010 RESUBMITTAL 06/11/2010 COMPLETED Review Details
05/07/2010 RESUBMITTAL - SITE ALL 06/11/2010 COMPLETED Review Details
06/14/2010 RESUBMITTAL - SITE 07/15/2010 COMPLETED Review Details
06/14/2010 RESUBMITTAL 06/14/2010 COMPLETED Review Details
06/14/2010 RESUBMITTAL 07/15/2010 COMPLETED Review Details
06/28/2012 REVISION - - 2ND 06/28/2012 COMPLETED Review Details
07/15/2010 RESUBMITTAL 07/15/2010 COMPLETED Review Details
12/10/2009 PLANS OK TO SUBMIT - COMM 12/10/2009 COMPLETED Review Details
12/10/2009 PLANS OK TO SUBMIT - SITE 12/10/2009 COMPLETED Review Details
12/10/2009 COMMERCIAL NEW 01/11/2010 COMPLETED Review Details
12/10/2009 SITE 01/11/2010 COMPLETED Review Details
12/14/2011 REVISION - - 1ST 12/14/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM03255
Permit Status: C of o
Permit Description: ADDITION:SHOP BUILDING
Total Outstanding Activity Conditions - 1
Date Name
12/10/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T09CM03255
Permit Description: ADDITION:SHOP BUILDING
Total Completed Inspections - 34
Date Description Inspector Results Comments
11/19/2010 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
12/17/2010 EXCAVATION/LAYOUT REBAR & ZON MHENSON Approved IVRS - Inspection :*
12/29/2010 REINFORCED MASONRY PRE-GROUT MHENSON Approved IVRS - Inspection :*
1) NEED CLARIFICATION 2 #5 OR 2 #4 AT STEM WALL BOND BEAM #4 USED
2) PROVIDE COMPLIANT SPECIAL INSPECTION
02/17/2011 PLUMBING - PRE SLAB RMYERS Approved IVRS - Inspection :*
03/04/2011 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
09/30/2011 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
NOT INSTALLED PER PLAN
PLAN SHOWS WATER HEATER ABOVE RESTROOM
PLAN SHOWS HOSE BIBB - COVER WATER ETC
NO TEST ON ABS
SUPPORT VERTICAL PIPING - VENT THRU ROOF TO BE 3"
04/30/2012 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
04/30/2012 FRAMING AQUIROZ Approved IVRS - Inspection :*
07/10/2012 ELECTRIC - CABLE DROP MPUGH Approved IVRS - Inspection :*
07/11/2012 TEP CLEARANCE - AM MPUGH Approved
11/09/2012 NPPO - FINAL DROBERTS Approved
11/09/2012 SIGN - FINAL DROBERTS Approved
11/09/2012 LANDSCAPE - FINAL DROBERTS Approved
11/09/2012 ENGINEERING - FINAL DROBERTS Approved
11/14/2012 ELECTRIC - ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
11/14/2012 ELECTRIC - INTERMEDIATE AQUIROZ Approved IVRS - Inspection :*
11/14/2012 ELECTRIC - OUTDOOR LIGHTING AQUIROZ Approved IVRS - Inspection :*
11/14/2012 ELECTRIC - UNDERGROUND AQUIROZ Approved IVRS - Inspection :*
11/14/2012 MECHANICAL - FINAL AQUIROZ Approved IVRS - Inspection :*
11/14/2012 MECHANICAL - INTERMEDIATE AQUIROZ Approved IVRS - Inspection :*
11/14/2012 BUILDING - PROGRESS AQUIROZ Approved IVRS - Inspection :*
11/15/2012 PLUMBING - FINAL MPUGH Approved IVRS - Inspection :*
11/15/2012 ELECTRIC - FINAL MPUGH Approved IVRS - Inspection :*
11/15/2012 ELECTRIC - PROGRESS MPUGH Approved IVRS - Inspection :*
11/16/2012 FIRE - FINAL WMOTTO Approved
11/16/2012 CERTIFICATE OF OCCUPANCY MPUGH Approved IVRS - Inspection :*
11/16/2012 BUILDING - FINAL MPUGH Approved IVRS - Inspection :*
11/19/2012 PLUMBING - PROGRESS MPUGH Approved PER FINAL
12/26/2012 RIGHT OF WAY - FINAL TWOLFGAN Approved PER PH CALL
12/26/2012 PLUMBING - ROUGH, SOIL MPUGH Approved PER PL FINAL
12/26/2012 BUILDING PRE-SLAB MPUGH Approved PER BU FINAL
12/26/2012 ELECTRIC - UFER MPUGH Approved PER EL FINAL
12/26/2012 OUTDOOR LIGHTING FINAL MPUGH Approved PER EL FINAL
12/26/2012 PLUMBING - YARD WTR LINE/TEST MPUGH Approved PER PL FINAL

Documents

File Name Document Type  
C OF O_12-26-2012.TIF CERT OF OCC VIEW
001_AS101.TIF CONSTRPLANS VIEW
002_S100.TIF CONSTRPLANS VIEW
003_S101.TIF CONSTRPLANS VIEW
004_S201.TIF CONSTRPLANS VIEW
005_A101.TIF CONSTRPLANS VIEW
006_A201.TIF CONSTRPLANS VIEW
007_P101.TIF CONSTRPLANS VIEW
008_M101.TIF CONSTRPLANS VIEW
009_E101.TIF CONSTRPLANS VIEW
010_E102.TIF CONSTRPLANS VIEW
011_E103.TIF CONSTRPLANS VIEW
012_E104.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW