Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T09CM03255
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2010 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | 1. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. Sidewalk or PAAL can not be located within landscape buffer. 2. A 6'screen along street frontages for outdoor storage must be provided per LUC Table 3.7.2-I. Indicate screening elements on the landscape plan. 3. A 30"continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I. Indicate screening elements on the landscape plan. 4. Storm water detention/retention basins shall be landscaped to enhance the natural configuration of the basin. Plants located in the bottom one-third (1/3) of the detention/retention basin must be adaptable to periods of submersion. Indicate treatment for basin on landscape plan. 5. Determine the disposition of Palo Verde Tree marked (D) within driveway entrance. 6. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan. 7. Additional comments may apply. |
| 05/13/2010 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 05/21/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 05/24/2010 | DAVID RIVERA | ZONING | REVIEW | Denied | Zoning cannot approve the building plan until the site plan has been approved. |
| 06/02/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | A point-of-use water dispenser will be acceptable in lieu of a bi-level drinking fountain provided that the cups are located in an accessible location. Locating a point-of-use water dispenser in a building that is to be built at some future date is not acceptable. Provide the minimum plumbing facilities required by Table 2902.1 and Section 2902.2, IBC 2006, for a factory and industrial occupancy. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/11/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 06/11/2010 | GERARDO BONILLA | REJECT SHELF | Completed |