Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
5660 S 12TH AV
Address NEW:
5660 S 12TH AV
Apply Date:
07/13/2009
Applicant:
N/A
Description:
CHARTER SCHOOL
Architects:
  • SHAMBACH, ROBIN ADELE
Contractors:
  • LOW MOUNTAIN CONSTRUCTION INC ,

Permit Reviews

Permit Number - T09CM01819
Permit Status: C of o
Permit Description: CHARTER SCHOOL
Start Date Submittal Complete Date Status  
07/13/2009 PLANS OK TO SUBMIT - COMM 07/13/2009 COMPLETED Review Details
07/13/2009 COMMERCIAL TI 07/28/2009 COMPLETED Review Details
07/28/2009 RESUBMITTAL 07/29/2009 COMPLETED Review Details
10/20/2009 REVISION - - 1ST 10/20/2009 COMPLETED Review Details
11/17/2009 SITE 11/17/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM01819
Permit Status: C of o
Permit Description: CHARTER SCHOOL
Total Outstanding Activity Conditions - 1
Date Name
07/13/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T09CM01819
Permit Description: CHARTER SCHOOL
Total Completed Inspections - 30
Date Description Inspector Results Comments
08/13/2009 FRAMING MHENSON Approved IVRS - Inspection :*
08/18/2009 SHEET ROCK NAILING MHENSON Approved IVRS - Inspection :*
1) RFI #1
08/21/2009 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
08/25/2009 BUILDING ABOVE CEILING MHENSON Approved IVRS - Inspection :*
1) OFFICE AREA ON 2ND FLOOR
09/23/2009 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
09/23/2009 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
09/24/2009 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
09/28/2009 MECHANICAL - HOODS MRAMBER Approved
09/28/2009 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
09/30/2009 FIRE - KITCHEN EXH HOOD FINAL DRAMIREZ Approved
10/01/2009 NPPO - FINAL JLINVILL Approved N/A
10/01/2009 LANDSCAPE - FINAL JLINVILL Approved N/A
10/01/2009 SIGN - FINAL JYBARRA Approved IVRS - Inspection : TENANT HAS INSTALLED NEW WALL SIGN & NEW CABINET FOR D/F SIGN; ALSO HAS BANNER ON FENCE
The occupancy inspection reveals that corrections are required. Please furni
10/01/2009 RIGHT OF WAY - FINAL LLOPEZ Approved PER EMAIL
10/01/2009 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
10/02/2009 FIRE - FINAL DRAMIREZ Approved 1.) Replace the ceiling tiles in the IT room.
2.) Portable fire extinguishers, required or non required, must be maintained and seviced or can be removed from service.
3.) Repair the panic hardware on the north double doors in room#110.
4.) Exit sign is burnt out in room #107.
5.) Replace all missing escusheons.
6.) Exit signs, exterior hall, ground floor are burnt out.
7.) Need a breaker blank, electrical panel. room # 105.
8.) Need a sign on the NW exterior gate that reads, "NOT AN EXIT"
9.) Can not direct towards a non exit door.(Exit sign next to room #106.
10.) The exit sign in room # 210 is burnt out.

OK to operate kitchen.
10/02/2009 FIRE - ALARM FINAL DRAMIREZ Approved
10/02/2009 FIRE SPKLR - FINAL DRAMIREZ Approved
10/06/2009 ENGINEERING - FINAL JFEMLING Approved 1) Final existing grading permit T00BU00724
2) Clear up outstanding zoning violation T04ZV00183
3) Address HC parking on North side of building that is out of compliance and Note 25 of the approved site and grading plan that calls for sidewalk scuppers at downspouts.
10/07/2009 BUILDING - FINAL MHENSON Approved IVRS - Inspection :*
1) OK TO USE RESTROOMS WITH PLUMBING OK
10/07/2009 PLUMBING - FINAL RLEDONNE Approved IVRS - Inspection :*
10/07/2009 PLUMBING - PROGRESS RLEDONNE Approved IVRS - Inspection :*
10/07/2009 PLUMBING - YARD WTR LINE/TEST RLEDONNE Approved IVRS - Inspection :*
10/07/2009 PLUMBING - ABOVE CEILING RLEDONNE Approved IVRS - Inspection :*
10/07/2009 PLUMBING - INTERMEDIATE RLEDONNE Approved IVRS - Inspection :*
10/07/2009 PLUMBING - PRE SLAB RLEDONNE Approved IVRS - Inspection :*
10/07/2009 PLUMBING - ROUGH, SOIL RLEDONNE Approved IVRS - Inspection :*
01/06/2010 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
02/23/2010 CERTIFICATE OF OCCUPANCY LHANLY Approved PARTIAL INSTALL WEATHER PROOF COVERS ON OUTLETS IN OPEN CORRIDORS.
02/23/2010 CERTIFICATE OF OCCUPANCY MHENSON Approved NEED WATERPROOF COVERS ON EXTERIOR OUTLETS.

Documents

File Name Document Type  
None CERT OF OCC VIEW
AMSCH1.JPG SIGNS VIEW
AMSCH2.JPG SIGNS VIEW
AMSCH3.JPG SIGNS VIEW
None DOCUMENTS VIEW
001_COVER.TIF CONSTRPLANS VIEW
002_G1.1.TIF CONSTRPLANS VIEW
003_G1.2.TIF CONSTRPLANS VIEW
004_C1.TIF CONSTRPLANS VIEW
005_PLAN.TIF CONSTRPLANS VIEW
006_PLAN.TIF CONSTRPLANS VIEW
007_D1.1.TIF CONSTRPLANS VIEW
008_A2.1.TIF CONSTRPLANS VIEW
009_A2.2.TIF CONSTRPLANS VIEW
010_A2.3.TIF CONSTRPLANS VIEW
011_A6.1.TIF CONSTRPLANS VIEW
012_A10.1.TIF CONSTRPLANS VIEW
013_M1.1.TIF CONSTRPLANS VIEW
014_M1.2.TIF CONSTRPLANS VIEW
015_M2.1.TIF CONSTRPLANS VIEW
016_M2.2.TIF CONSTRPLANS VIEW
017_M3.1.TIF CONSTRPLANS VIEW
018_P1.1.TIF CONSTRPLANS VIEW
019_P1.2.TIF CONSTRPLANS VIEW
020_P2.1.TIF CONSTRPLANS VIEW
021_P2.2.TIF CONSTRPLANS VIEW
022_E0.1.TIF CONSTRPLANS VIEW
023_E1.1.TIF CONSTRPLANS VIEW
024_E2.1.TIF CONSTRPLANS VIEW
025_E3.1.TIF CONSTRPLANS VIEW
026_E4.1.TIF CONSTRPLANS VIEW
001_E2.1.TIF CONSTRPLANS VIEW
002_E3.1.TIF CONSTRPLANS VIEW
003_E4.1.TIF CONSTRPLANS VIEW
001_SITE PLAN.TIF CONSTRPLANS VIEW