Permit: T09CM01559
Permit Details
Apply Date:
06/17/2009
Applicant:
N/A
Description:
ADDT: BATH RM, BED RM AND RELOCATE WASHER R1 - GAS LINE
Permit Reviews
Permit Number - T09CM01559
Permit Status: Final
Permit Description: ADDT: BATH RM, BED RM AND RELOCATE WASHER
R1 - GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/17/2009 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 06/19/2009 | COMPLETED |
| 10/08/2009 | REVISION - - 1ST | 10/08/2009 | COMPLETED |
| 12/10/2009 | REVISION - - 2ND | 12/11/2009 | COMPLETED |
| 12/28/2009 | REVISION - - 3RD | 02/25/2020 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM01559
Permit Status: Final
Permit Description: ADDT: BATH RM, BED RM AND RELOCATE WASHER
R1 - GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/17/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM01559
Permit Description: ADDT: BATH RM, BED RM AND RELOCATE WASHER
R1 - GAS LINE
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2009 | PLUMBING - ROUGH, SOIL | DQUINN | Approved | IVRS - Inspection :* |
| 07/20/2009 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* 1) PLUMBING WRAPS IN PLACE |
| 07/20/2009 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* |
| 08/11/2009 | ROOF NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 08/11/2009 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection :* |
| 09/03/2009 | STUCCO MESH | EDURAZO | Approved | IVRS - Inspection :* |
| 11/19/2009 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* 1) NEW GAS LINE TAPED AND WIRED & OK TO BACKFILL 2) NEED PRESSURE TEST |
| 11/25/2009 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* 1) NEW PIPING WITH TEST IS OK 2) PROVIDE INSTALLATION INSTRUCTIONS FOR BOSCH WH 3) VENTING MAY NOT BE RIGHT 4) CALL FOR MECHANICAL INSPECTION OF NEW FAU AND CORRECTLY SIZED FLEX |
| 11/30/2009 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER NOT LOCATED PER PLAN-PROVIDE REVISION, COMBUSTION AIR CONSIDERATIONS MUST BE ADDRESSED, REVISE GAS PLAN ALSO 2) PROVIDE DRAINAGE FITTING, AND MAX 1/4" SLOPE ON LAV TRAP ARM, OR INSTALL IT PER PLAN 3) PROVIDE A WATER TEST ON TUB 4) EXCESS FLUX SHOULD BE WIPED FROM SOLDER JOINTS |
| 12/24/2009 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 12/24/2009 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 02/19/2010 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 02/25/2010 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 07/22/2010 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 07/27/2010 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 07/27/2010 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 08/03/2010 | PERMIT FINALED | JWEATHER | Approved |