Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 01/20/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE APPROVED PLANS AND ALL INSPECTIONS |
|
| 01/13/2010 | PLUMBING - INTERMEDIATE | Cancelled | CANCELLED PER HOMEOWNER FRANCIS ARANA #318-1510 | |
| 01/13/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 01/12/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PLAN REVISION OK 2) PROVIDE COMBUSTION AIR OPENINGS AS INDICATED 3) SECURE PIPING ABOVE ROOF 4) CALL FOR MECHANICAL FINAL INSPECTION OF NEW FAV 5) CORRECT B-VENT AT EXISTING WATER HEATER WITHOUT INSPECTION 6) CAP ABANDONED RISER AND REMOVE OLD GAS VALVE |
|
| 11/30/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER NOT LOCATED PER PLAN-PROVIDE REVISION, COMBUSTION AIR CONSIDERATIONS MUST BE ADDRESSED, REVISE GAS PLAN ALSO 2) PROVIDE DRAINAGE FITTING, AND MAX 1/4" SLOPE ON LAV TRAP ARM, OR INSTALL IT PER PLAN 3) PROVIDE A WATER TEST ON TUB 4) EXCESS FLUX SHOULD BE WIPED FROM SOLDER JOINTS |