Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/19/2010 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 02/12/2010 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UNSAFE ROOF ACCESS 2) LADDER SHALL EXTEND 30" ABOVE ROOF AND SECURED NO A FRAME LADDERS 3) I WILL NOT ENTER OCCUPIED HOUSE WITHOUT ADULT BEING PRESENT |
|
| 02/08/2010 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ANSWER AT FRONT DOOR 8:27 AM 2) NO ACCESS |
|
| 01/28/2010 | MECHANICAL - FINAL | Cancelled | CANCELLED PER HOMEOWNER FRANCIS ARANA #318-1510 | |
| 01/28/2010 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 01/22/2010 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 01/13/2010 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A CONDENSATE DRAIN TO AN APPROVED LOCATION 2) NEED TO SEE R8 INSULATION INSIDE NEW DUCT ON ROOF 3) SUPPORT ELECTRIC CONDUIT 4) PROVIDE A GFI SERVICE RECEPT ON ROOF WITH A BUBBLE TYPE COVER 5) ALL DUCT IN A VENTILATED ATTIC MUST BE R8 6) FINISH VENTING EXISTING WATER HEATER |