Permit: T09BU00395
Permit Details
Status:
Expired
Type:
Grading and SWPPP
Address:
10000 E OLD VAIL RD
Address NEW:
10000 E OLD VAIL RD
Apply Date:
03/17/2009
Applicant:
N/A
Description:
GRADING
Contractors:
- MW MORRISSEY CONSTRUCTION LLC
Permit Reviews
Permit Number - T09BU00395
Permit Status: Expired
Permit Description: GRADING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/17/2009 | PLANS OK TO SUBMIT - GRADING | 03/17/2009 | COMPLETED |
| 03/17/2009 | GRADING | 04/07/2009 | COMPLETED |
| 03/17/2009 | SWPPP | 04/06/2009 | COMPLETED |
| 09/16/2013 | PLANS OK TO SUBMIT - GRADING | 09/26/2013 | COMPLETED |
| 12/11/2009 | RESUBMITTAL - GRADING ALL | 09/16/2013 | COMPLETED |
| 12/15/2009 | RESUBMITTAL - SWPPP | 12/15/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09BU00395
Permit Status: Expired
Permit Description: GRADING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/17/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T09BU00395
Permite Description: GRADING
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/08/2015 | GRADING - TIER REV | N/A | Correction Required | 1) REVISIONS MADE TO THE ORIGINAL GRADING PLAN. CHANGED ENGINEERING COMPANIES AND CIVIL ENGINEER. CONTRACTOR HAS THE APPROVED REVISED PLANS ON SITE. 2) NEED ENGINEER APPROVAL FOR CHANGE OF CONCRETE OUTFALL DRAINAGEWAYS ALONG THE NORTH SIDE OF SITE. CONTRACTOR WANTS TO SHOT CRETE THE DRAINAGEWAYS INSTEAD OF FORM AND POUR DUE TO SLOPE ELEVATIONS. 3) ADDITION OF A WALL ALONG THE EAST PERIMETER WITH ROCK RIP RAP ON SLOPE. 4) NEED PERMIT AND INSPECTIONS FOR RETAINING WALL ALONG THE NORTH PERIMETER. 5) NEED REPAIR AND STABILIZATION OF NORTH SLOPE. BRING SPOILS BACK ON SITE |
| 10/15/2020 | ENGINEERING - FINAL | N/A | Not ready for Inspection | NOT READY AT THIS TIME, THIS WILL BE RESCHEDULED AT A LATER DATE BY THE CONTRACTOR |
| 11/05/2013 | LANDSCAPE INSPECTION | N/A | Continued | 1) SEDIMENT CONTROLS HAVE BEE INSTALLED ALONG THE PERIMETER OF THE SITE. 2) PLANTS IDENTIFIED ON THE NPPO PLAN HAVE BEEN TAGGED AND RE-PLANTED ON SITE |
| 12/27/2018 | GRADING - INTERMEDIATE | N/A | Correction Required | 10LIGHT POLE FOUNDATIONS HAVE BEEN APPROVED IN THE PHASE 2 PORTION OF THIS SITE |
Completed Inspections
Permit Status: Expired
Permit Number: T09BU00395
Permit Description: GRADING
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2013 | NPPO PRE PERMIT INSPECTION | MRUSSO | Approved | 1) MET WITH SUPERINTENDENT TO DISCUSS STORM WATER, NPPO, AND GRADING REQUIREMENTS 2) CONTRACTOR WILL INSTALL SEDIEMNT CONTROLS PER THE APPROVED SWPPP 3) THE LANDSCAPE SUBCONTRACTOR WILL FLAG TREES TO BE PRESERVED AND TRANSPLANT TREES TO BE SAVED. 4) ENSURE STORM WATER SELF INSPECTIONS ARE PERFORMED AND DOCUMENTED. 5) POST A COPY OF YOUR NOI AT THE ENTRANCE TO THE SITE 6) INSTALL AND USE A CONCRETE/MATERIALS WASH OUT AS NEEDED 7) SWEEP UP ANY TRACKED SOIL OFF ADJACENT ROADWAYS |
| 10/01/2013 | ENGINEERING PRE-CONSTRUCTION | MRUSSO | Approved | 1) MET WITH SUPERINTENDENT TO DISCUSS STORM WATER, NPPO, AND GRADING REQUIREMENTS 2) CONTRACTOR WILL INSTALL SEDIEMNT CONTROLS PER THE APPROVED SWPPP 3) THE LANDSCAPE SUBCONTRACTOR WILL FLAG TREES TO BE PRESERVED AND TRANSPLANT TREES TO BE SAVED. 4) ENSURE STORM WATER SELF INSPECTIONS ARE PERFORMED AND DOCUMENTED. 5) POST A COPY OF YOUR NOI AT THE ENTRANCE TO THE SITE 6) INSTALL AND USE A CONCRETE/MATERIALS WASH OUT AS NEEDED 7) SWEEP UP ANY TRACKED SOIL OFF ADJACENT ROADWAYS |
| 11/05/2013 | STORMWATER INSTALL OF CONTROLS | MRUSSO | Approved | 1) SEDIMENT CONTROLS HAVE BEE INSTALLED ALONG THE PERIMETER OF THE SITE. 2) PLANTS IDENTIFIED ON THE NPPO PLAN HAVE BEEN TAGGED AND RE-PLANTED ON SITE |