Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
08/21/2008
Applicant:
N/A
Description:
TI: RESTAURANT
Contractors:
  • HAWORTH CORPORATION , THE

Permit Reviews

Permit Number - T08CM02847
Permit Status: C of o
Permit Description: TI: RESTAURANT
Start Date Submittal Complete Date Status  
01/13/2009 3RD PARTY REVIEW-REVISION/OTHER 01/23/2009 COMPLETED Review Details
08/21/2008 PLANS OK TO SUBMIT - 3RD PARTY 08/22/2008 COMPLETED Review Details
08/22/2008 3RD PARTY REVIEW-COMMERCIAL TI 10/07/2008 COMPLETED Review Details
08/28/2008 POST 3RD PARTY REVIEW 12/16/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM02847
Permit Status: C of o
Permit Description: TI: RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
08/21/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM02847
Permit Description: TI: RESTAURANT
Total Completed Inspections - 41
Date Description Inspector Results Comments
11/13/2008 EXCAVATION/LAYOUT REBAR & ZON IVR USER Approved IVRS - RI canceled
11/17/2008 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
SHAWN @ 602-332-2052

WATER TEST DWV & GREASE WASTE THRU BLD. TO EXISTING POINT OF CONNECTION OK
11/19/2008 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
REVISED PLANS DATED 9/24/08 -- SLAB AT PER REVISED PLANS -- OK TO POUR
11/19/2008 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
12/03/2008 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
OK TO INSULATE DUCTS
INSTALL FLEX DUCTS PER DETAIL ON PLANS
USE ONLY UL181 LISTED TAPE AND METAL BANDS
SUPERINTENDENT: SEAN
12/08/2008 BUILDING - PROGRESS GDABBS Approved IVRS - Inspection :*
12/10/2008 MECHANICAL - HOOD SYSTEMS JMILITEL Approved IVRS - Inspection :*
CHECKED 1ST LAYER OF FIRE WRAP
OK FOR 2ND LAYER
PROVIDE HEAT SENSORS IN EXHAUST DUCTS
12/11/2008 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*
FIRE WRAP OK
OK TO SHEETROCK HARD LIDS AND SOFFITS
12/11/2008 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
1. FAN BOXES TO BE LISTED FOR USE FOR FANS
2. PIPES ABOVE PANEL IN EQUIPMENT DEDICATED SPACE NEED TO BE MOVED - NEC 110.26
3. OK WALLS AND HARD LIDS MAKE CORRECTION AS ABOVE
12/11/2008 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
12/11/2008 FRAMING GDABBS Approved IVRS - Inspection :*
12/12/2008 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
TEST ON GAS PIPING FROM METER TO CAPS AT APPLIANCES THRU ANSUL VALVE

1. NEED INSTALLATION OF SLEEVING ON GAS PIPING PER PLAN WITH DETAIL FOR HOW TO
2. NEED RETEST WHEN VALVES ARE INSTALLED WITH CONTINUATION TO ROOFTOP UNIT.
12/16/2008 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
IN WALL INSULATION OK
12/22/2008 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TAPE THROUGHOUT -- ALL CEILINGS ARE COMPLETE
01/02/2009 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
01/07/2009 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO SET CEILING TILES
01/07/2009 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
01/07/2009 STUCCO MESH JBURGE Approved IVRS - Inspection :*
01/16/2009 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED FOR #E04 PER R. JIROUDEK
01/21/2009 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
PLEASE READ ALL NOTES, CALL IN ALL PLUMBING INSPECTIONS FOR APPROVAL PRIOR TO FINAL INSPECTION.
01/22/2009 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
EXTEND AIR INTAKE VENT FOR WATER HEATER AS PER INSTALL INSTRUCTIONS
01/22/2009 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
01/27/2009 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
01/27/2009 FIRE - KITCHEN EXH HOOD FINAL CSCHULTZ Approved
01/27/2009 FIRE SPKLR - FINAL CSCHULTZ Approved
01/27/2009 FIRE - FINAL CSCHULTZ Approved
01/28/2009 PLUMBING - FINAL RRICH Approved COMPLETE ALL ITEMS LISTED ON 1/27/09
01/28/2009 PLUMBING - FINAL RRICH Approved AFTER HRS. INSP. PAID CHECK#02610 - $150.00
CORRECTIONS MADE
01/28/2009 PLUMBING - PROGRESS RRICH Approved
01/28/2009 PLUMBING - GAS RECONNECT RRICH Approved
01/28/2009 NPPO - FINAL ACONNOR Approved N/A
01/28/2009 LANDSCAPE - FINAL ACONNOR Approved N/A
01/28/2009 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
01/28/2009 ELECTRIC - PROGRESS RJIROUDE Approved IVRS - Inspection :*
01/28/2009 ELECTRIC - TEMP POWER FOR TEST RJIROUDE Approved IVRS - Inspection :*
01/29/2009 ENGINEERING - FINAL NKALAHAR Approved AP

GAVE SHAWN 602 992 2052 CONTACT INFO FOR SIGNS
01/29/2009 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
01/29/2009 ENGINEERING - FINAL NKALAHAR Approved CLEAN UP AROUND DUMPSTERS
WAIT FOR PAINTERS TO FINISH
01/30/2009 RIGHT OF WAY - FINAL MCASTRO Approved
01/30/2009 SIGN - FINAL LHANLY Approved permits obtained for door signs. other sign on separate permit not part of this work shall have inspections done as part of separate permit.
01/30/2009 HEALTH DEPT - FINAL 724-7908 LGERINGER Approved