Permit: T08CM02847

Parcel: 12801005H

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
11/17/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
SHAWN @ 602-332-2052

WATER TEST DWV & GREASE WASTE THRU BLD. TO EXISTING POINT OF CONNECTION OK
11/14/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE CORRECT DRAINAGE FITTINGS AT VENT TAKE-OFF's
COMBOS - OR WYE + 1/6" BENDS SWEEPS
3" SHOWN AT MS
PROVIDE A DIRECT CONN. FOR 4-COMP SINK
FULLSIZE CLEANOUTS
11/13/2008 PLUMBING - ROUGH, SOIL Cancelled IVRS - RI canceled