Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM02847

Parcel: 12801005H

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM02847

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/28/2009 PLUMBING - FINAL Approved AFTER HRS. INSP. PAID CHECK#02610 - $150.00
CORRECTIONS MADE
01/28/2009 PLUMBING - FINAL Not ready for Inspection COMPLETE ALL ITEMS LISTED ON 1/27/09
01/27/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CLOSET FLANGES OK

CALL IN ALL PLUMBING INSPECTIONS

1. SECURE TEMPERING VALVES AT LAVS
2. INSTALL SAFETY CABLES ON GAS APPLIANCES WITH WHEELS
3. MAKE ALL FIXTURES WATER TIGHT
4. PROVIDE APPROVED CLEANOUT PLUGS FACTORY TAPPED WITH MACHINE SCREWS FOR CLEANOUT COVERS
5. ALL INDIRECT DRAINS TO HAVE MINIMUM 1" AIR GAP AT TERMINATIONS
6. SUPPORT PIPING & RPB AT ICE MACHINE
7. PROVIDE CORRECT DRAIN CONNECTION FOR 4-BOWL
OF SINK
8. PROVIDE APPROVED DRAINAGE FOR SOFTENER
9. PROVIDE CORRECT DRAIN FOR SODA DISPENSER
10. PROVIDE CHLORINE & BACTERIA REPORT FOR POTABLE WATER SYSTEM