Permit Number - T08CM02847
Permit Status: C of o
Permit Description: TI: RESTAURANT
Start Date Submittal Complete Date Status  
01/13/2009 3RD PARTY REVIEW-REVISION/OTHER 01/23/2009 COMPLETED Review Details
08/21/2008 PLANS OK TO SUBMIT - 3RD PARTY 08/22/2008 COMPLETED Review Details
08/22/2008 3RD PARTY REVIEW-COMMERCIAL TI 10/07/2008 COMPLETED Review Details
08/28/2008 POST 3RD PARTY REVIEW 12/16/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM02847
Permit Status: C of o
Permit Description: TI: RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
08/21/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM02847
Permit Description: TI: RESTAURANT
Total Completed Inspections - 41
Date Description Inspector Results Comments
11/13/2008 EXCAVATION/LAYOUT REBAR & ZON IVR USER Approved IVRS - RI canceled
11/17/2008 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
SHAWN @ 602-332-2052

WATER TEST DWV & GREASE WASTE THRU BLD. TO EXISTING POINT OF CONNECTION OK
11/19/2008 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
REVISED PLANS DATED 9/24/08 -- SLAB AT PER REVISED PLANS -- OK TO POUR
11/19/2008 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
12/03/2008 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
OK TO INSULATE DUCTS
INSTALL FLEX DUCTS PER DETAIL ON PLANS
USE ONLY UL181 LISTED TAPE AND METAL BANDS
SUPERINTENDENT: SEAN
12/08/2008 BUILDING - PROGRESS GDABBS Approved IVRS - Inspection :*
12/10/2008 MECHANICAL - HOOD SYSTEMS JMILITEL Approved IVRS - Inspection :*
CHECKED 1ST LAYER OF FIRE WRAP
OK FOR 2ND LAYER
PROVIDE HEAT SENSORS IN EXHAUST DUCTS
12/11/2008 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*
FIRE WRAP OK
OK TO SHEETROCK HARD LIDS AND SOFFITS
12/11/2008 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
1. FAN BOXES TO BE LISTED FOR USE FOR FANS
2. PIPES ABOVE PANEL IN EQUIPMENT DEDICATED SPACE NEED TO BE MOVED - NEC 110.26
3. OK WALLS AND HARD LIDS MAKE CORRECTION AS ABOVE
12/11/2008 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
12/11/2008 FRAMING GDABBS Approved IVRS - Inspection :*
12/12/2008 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
TEST ON GAS PIPING FROM METER TO CAPS AT APPLIANCES THRU ANSUL VALVE

1. NEED INSTALLATION OF SLEEVING ON GAS PIPING PER PLAN WITH DETAIL FOR HOW TO
2. NEED RETEST WHEN VALVES ARE INSTALLED WITH CONTINUATION TO ROOFTOP UNIT.
12/16/2008 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
IN WALL INSULATION OK
12/22/2008 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TAPE THROUGHOUT -- ALL CEILINGS ARE COMPLETE
01/02/2009 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
01/07/2009 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO SET CEILING TILES
01/07/2009 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
01/07/2009 STUCCO MESH JBURGE Approved IVRS - Inspection :*
01/16/2009 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED FOR #E04 PER R. JIROUDEK
01/21/2009 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
PLEASE READ ALL NOTES, CALL IN ALL PLUMBING INSPECTIONS FOR APPROVAL PRIOR TO FINAL INSPECTION.
01/22/2009 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
EXTEND AIR INTAKE VENT FOR WATER HEATER AS PER INSTALL INSTRUCTIONS
01/22/2009 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
01/27/2009 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
01/27/2009 FIRE - KITCHEN EXH HOOD FINAL CSCHULTZ Approved
01/27/2009 FIRE SPKLR - FINAL CSCHULTZ Approved
01/27/2009 FIRE - FINAL CSCHULTZ Approved
01/28/2009 PLUMBING - FINAL RRICH Approved COMPLETE ALL ITEMS LISTED ON 1/27/09
01/28/2009 PLUMBING - FINAL RRICH Approved AFTER HRS. INSP. PAID CHECK#02610 - $150.00
CORRECTIONS MADE
01/28/2009 PLUMBING - PROGRESS RRICH Approved
01/28/2009 PLUMBING - GAS RECONNECT RRICH Approved
01/28/2009 NPPO - FINAL ACONNOR Approved N/A
01/28/2009 LANDSCAPE - FINAL ACONNOR Approved N/A
01/28/2009 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
01/28/2009 ELECTRIC - PROGRESS RJIROUDE Approved IVRS - Inspection :*
01/28/2009 ELECTRIC - TEMP POWER FOR TEST RJIROUDE Approved IVRS - Inspection :*
01/29/2009 ENGINEERING - FINAL NKALAHAR Approved AP

GAVE SHAWN 602 992 2052 CONTACT INFO FOR SIGNS
01/29/2009 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
01/29/2009 ENGINEERING - FINAL NKALAHAR Approved CLEAN UP AROUND DUMPSTERS
WAIT FOR PAINTERS TO FINISH
01/30/2009 RIGHT OF WAY - FINAL MCASTRO Approved
01/30/2009 SIGN - FINAL LHANLY Approved permits obtained for door signs. other sign on separate permit not part of this work shall have inspections done as part of separate permit.
01/30/2009 HEALTH DEPT - FINAL 724-7908 LGERINGER Approved

Documents

File Name Document Type  
C OF O_01-30-2009.TIF CERT OF OCC VIEW
001__A000.TIF CONSTRPLANS VIEW
002__A001.TIF CONSTRPLANS VIEW
003__A002.TIF CONSTRPLANS VIEW
004__A010.TIF CONSTRPLANS VIEW
005__A011.TIF CONSTRPLANS VIEW
006__A012.TIF CONSTRPLANS VIEW
007__A013.TIF CONSTRPLANS VIEW
008__A103.TIF CONSTRPLANS VIEW
009__A110.TIF CONSTRPLANS VIEW
010__A111.TIF CONSTRPLANS VIEW
011__A115.TIF CONSTRPLANS VIEW
012__A116.TIF CONSTRPLANS VIEW
013__A117.TIF CONSTRPLANS VIEW
014__A120.TIF CONSTRPLANS VIEW
015__A125.TIF CONSTRPLANS VIEW
016__A130.TIF CONSTRPLANS VIEW
017__A131.TIF CONSTRPLANS VIEW
018__A140.TIF CONSTRPLANS VIEW
019__A141.TIF CONSTRPLANS VIEW
020__A150.TIF CONSTRPLANS VIEW
021__A200.TIF CONSTRPLANS VIEW
022__A210.TIF CONSTRPLANS VIEW
023__A220.TIF CONSTRPLANS VIEW
024__A225.TIF CONSTRPLANS VIEW
025__A230.TIF CONSTRPLANS VIEW
026__A300.TIF CONSTRPLANS VIEW
027__A310.TIF CONSTRPLANS VIEW
028__S000.TIF CONSTRPLANS VIEW
029__S100.TIF CONSTRPLANS VIEW
030__F100.TIF CONSTRPLANS VIEW
031__MP010.TIF CONSTRPLANS VIEW
032__M100.TIF CONSTRPLANS VIEW
033__M200.TIF CONSTRPLANS VIEW
034__M300.TIF CONSTRPLANS VIEW
035__P100.TIF CONSTRPLANS VIEW
036__P110.TIF CONSTRPLANS VIEW
037__P200.TIF CONSTRPLANS VIEW
038__P300.TIF CONSTRPLANS VIEW
039__E010.TIF CONSTRPLANS VIEW
040__E100.TIF CONSTRPLANS VIEW
041__E110.TIF CONSTRPLANS VIEW
042__E200.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW