Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address NEW:
1824 E 12TH ST #01
Apply Date:
06/05/2008
Applicant:
N/A
Description:
ADDITION:GUEST HOUSE W/KITCHEN R1: CHANGE FOUNDATION PLAN
Contractors:
  • MOCA CONSTRUCTION L L C

Permit Reviews

Permit Number - T08CM01924
Permit Status: Final
Permit Description: ADDITION:GUEST HOUSE W/KITCHEN R1: CHANGE FOUNDATION PLAN
Start Date Submittal Complete Date Status  
03/05/2009 REVISION - - 1ST 03/06/2009 COMPLETED Review Details
06/05/2008 PLANS OK TO SUBMIT - RES 06/05/2008 COMPLETED Review Details
06/05/2008 RESIDENTIAL BLDG/WWM 07/23/2008 COMPLETED Review Details
08/06/2008 RESUBMITTAL 08/27/2008 COMPLETED Review Details
08/27/2008 RESUBMITTAL 01/22/2009 COMPLETED Review Details
09/18/2012 REVISION - - 2ND 09/18/2012 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM01924
Permit Status: Final
Permit Description: ADDITION:GUEST HOUSE W/KITCHEN R1: CHANGE FOUNDATION PLAN
Total Outstanding Activity Conditions - 1
Date Name
06/05/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T08CM01924
Permit Description: ADDITION:GUEST HOUSE W/KITCHEN R1: CHANGE FOUNDATION PLAN
Total Completed Inspections - 24
Date Description Inspector Results Comments
06/03/2010 PLUMBING - ROUGH, SOIL DQUINN Approved IVRS - Inspection :*
06/16/2010 BUILDING PRE-SLAB EDURAZO Approved IVRS - Inspection :*
06/16/2010 EXCAVATION/LAYOUT REBAR & ZON EDURAZO Approved IVRS - Inspection :*
06/17/2010 STEM WALL/RETAINING WALL EDURAZO Approved IVRS - Inspection :*
06/17/2010 ELECTRIC - UFER EDURAZO Approved IVRS - Inspection :*
07/23/2012 EXT METAL CLIPS/EXT SHEATHING DQUINN Approved IVRS - Inspection :*
OK TO MOVE NW BED WINDOW FROM NORTH WALL TO WEST WALL
07/23/2012 ROOF NAILING DQUINN Approved IVRS - Inspection :*
07/31/2012 PLUMBING - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
08/09/2012 ELECTRIC - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
08/17/2012 U VALUE FOR WINDOW DSANTACR Approved IVRS - Inspection :*
08/17/2012 FRAMING DSANTACR Approved IVRS - Inspection :*
08/24/2012 STUCCO MESH MRAMBER Approved IVRS - Inspection :*
08/27/2012 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
09/04/2012 SHEET ROCK NAILING DSANTACR Approved IVRS - Inspection :*
09/19/2012 PLUMBING - SEWER HCS CONNECT RMYERS Approved
09/21/2012 ELECTRIC - UNDERGROUND RMYERS Approved
10/12/2012 ELECTRIC - SERVICE UPGRADE MRAMBER Approved IVRS - Inspection :*
10/15/2012 TEP CLEARANCE - AM RAMBER Approved #01 INCR OK TO CLEAR
#02 TMPP OK TO CLEAR
11/28/2012 MECHANICAL - FINAL MRAMBER Approved DUCT EXPOSED TO EXTERIOR IS TO HAVE A MINIMUM R-VALUE RATING OF 8 (2" LINER) 1" LINER ONLY PROVIDES A 4-2 RATING. CONDENSATE TO HAVE P-TRAP PER INSTALLATION INSTRUCTIONS. T-STAT WIRE IS TO BE INSTALLED IN PROTECTING CONDUIT WHEN EXPOSED TO EXTERIOR.
11/28/2012 OUTDOOR LIGHTING FINAL MRAMBER Approved IVRS - Inspection :*
12/27/2012 PLUMBING - FINAL JMILITEL Approved IVRS - Inspection :*
12/27/2012 PLUMBING - YARD WTR LINE/TEST JMILITEL Approved IVRS - Inspection :*
12/27/2012 ELECTRIC - FINAL JMILITEL Approved IVRS - Inspection :* THE CIRCUIT TO THE A/C UNIT IS NOT LARGE ENOUGH FOR THE A/C AND HEAT STRIP. PROVIDE A 90 DEGREE ELBOW AT TOP TERMINATION
02/14/2013 BUILDING - FINAL DSANTACR Approved

Documents

File Name Document Type  
001_SITE.TIF CONSTRPLANS VIEW
002_FOUNDATION.TIF CONSTRPLANS VIEW
003_ROOF.TIF CONSTRPLANS VIEW
004_FOUNDATION.TIF CONSTRPLANS VIEW
005_DETAIL.TIF CONSTRPLANS VIEW
006_FRAMING.TIF CONSTRPLANS VIEW
007_ELEC.TIF CONSTRPLANS VIEW
008_8.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW